23
that (32767 seconds). The camera automatically performs a
touchup when the camera changes temperature by 2°C. With
this setting one of the User Control Switch functions can be
assigned to perform Manual Touch-up for improved image
quality.
Display Icons turns symbology elements ON/OFF in the
display.
o
Temperature Number displays the value of the
temperature reading in the scene. The temperature
reading is taken by sampling the center 4×4 pixels of
the scene. This is centered about the crosshair.
o
C-F Character displays the units of the temperature
reading (C for degree Celcius and F for degree
Farhenheit). The Temperature Units zone is used to
select the temperature units.
o
Crosshair turns on the + symbol in the center of the
display.
Apply Changes applies your changes to the camera and saves
them to camera memory so that it uses this configuration every
time the camera is powered up. To save your changes, click on
Содержание X320