Section B: Preparing the Building for Heater Installation

Section C: Mounting the Heater and Completion

1. 

  Unfold the template provided in the kit.

2. 

 Use the template for determining the proper location of the heater with its mounting brackets, 
and for cutting out the hole needed for the ducting.

3. 

Read and comply with all installation instructions and information given on the template.

1. 

  After the duct hole has been cut, and stud locations identifi ed, center the wall brackets at 
marks made on studs. Position the brackets so the holed mounting fl anges are pointing in 
opposite directions. See Fig. 12. Temporarily attach the brackets with nails at upper holes. 
See Fig. 13.

FIG. 12

FIG. 13

Centered

at studs

Flanges 

pointed in 

opposite 

directions

Nail holes

Содержание GUARDIAN Smart Sense AD250

Страница 1: ...nstructions 1 30753 Outdoor Top 1 20257 Wall Bracket Burner End 1 24054 Wall Bracket Motor End 1 24053 Duct Assembly 1 24472 Duct Trim 2 24073 Duct Bracket 2 20092 Heater Duct Flange 1 24072 Hardware...

Страница 2: ...rovided sealant around back of duct flange See Fig 2 FIG 2 3 Attach the heater duct flange to outlet of heater using the blower outlet screws Ensure wide margin of flange is at top See Fig 3 FIG 3 4 U...

Страница 3: ...e inside corner of the mounting flange See Fig 5 FIG 5 6 Position duct into mounting flange so dampers lift up and away from blower outlet Push duct firmly against flange Attach duct to flange using 3...

Страница 4: ...allation Kit AD250 AW250 4 7 Remove the four cage nuts from corners of heater s case top Install hole plugs Press the plugs firmly to lock into hole See Figs 8 and 9 FIG 8 FIG 9 8 Fold the four tabs o...

Страница 5: ...250 AW250 5 FIG 10 9 Center the top onto heater Top slopes away from duct side of heater Secure top to heater with eight 8 x 1 2 in self drilling screws four at front four at back See Fig 11 FIG 11 Un...

Страница 6: ...ackets and for cutting out the hole needed for the ducting 3 Read and comply with all installation instructions and information given on the template 1 After the duct hole has been cut and stud locati...

Страница 7: ...bly and slide the duct assembly through the wall opening 4 Position the heater so duct is flush with inner wall of building and holes in base align to holes in brackets 5 Insert spacers between the op...

Страница 8: ...IN MINIMUM WALL TRIM PIECES DUCT 24 IN MINIMUM GROUND 7 Fill in void around duct with non combustible insulation 8 Seal the edges of duct hole at interior and exterior of building Use waterproof caul...

Страница 9: ...gas and electrical supplies Check for gas leaks 10 Start the heater Test the installation Dampers must open and close completely when heater is started and stopped 11 Refer to schematic for a general...

Страница 10: ...Outdoor Installation Kit www lbwhite com Outdoor Installation Kit AD250 AW250 10 Schematic and Parts List...

Страница 11: ...Outdoor Installation Kit Outdoor Installation Kit AD250 AW250 11 Notes...

Страница 12: ...0 345 7200 for assistance or email us at customerservice lbwhite com Be sure that you have your heater model number and configuration number when calling Service WORLD PROVIDER INNOVATIVE HEATING SOLU...

Страница 13: ...te de pared extremo del quemador 1 24054 Soporte de pared extremo del motor 1 24053 Unidad del conducto 1 24472 Moldura del conducto 2 24073 Soporte del conducto 2 20092 Reborde removible del calentad...

Страница 14: ...del reborde del conducto Vea la fig 2 FIG 2 3 Fije el reborde removible del calentador a la salida del calentador usando los tornillos para la salida del ventilador Aseg rese de que la parte ancha del...

Страница 15: ...fig 5 FIG 5 6 Posicione el conducto dentro del reborde de montaje de modo que los reguladores de flujo de aire se le vanten en sentido opuesto a la salida del ventilador Presione el conducto firmement...

Страница 16: ...97 4 7 Retire las cuatro tuercas enjauladas que est n en las esquinas de la tapa de la cubierta del calentador Instale los tapones para agujeros Presione los tapones firmemente para que se enganchen e...

Страница 17: ...tapa sobre el calentador La tapa se inclina en sentido contrario al lado del conducto del calen tador Asegure la tapa al calentador con ocho tornillos autoperforantes No 8 x 1 2 cuatro en la parte fr...

Страница 18: ...ecesario para el conducto 3 Lea y cumpla con todas las instrucciones y toda la informaci n sobre la instalaci n que se proporciona en la plantilla 1 Despu s de cortar el agujero del conducto y despu s...

Страница 19: ...red 4 Posicione el calentador de modo que el conducto est al ras con la pared interior de la edificaci n y los agujeros en la base se alineen con los agujeros en los soportes 5 Inserte los espaciadore...

Страница 20: ...e el hueco alrededor del conducto con aislante no combustible 8 Selle los bordes del agujero del conducto en el interior y exterior de la edificaci n Utilice sellador im permeable Si lo desea instale...

Страница 21: ...os de gas y electricidad Verifique que no haya fugas de gas 10 Encienda el calentador Pruebe la instalaci n Los reguladores de flujo de aire deber n abrir y cerrar por completo al encender y apagar el...

Страница 22: ...07863 SELF DRILLING SCREW 8 X 1 2 2 24073 DUCT TRIM 02330 SCREW 8 X 3 4 16 24472 DUCT ASSEMBLY 09183 DUCT BRACKET 2 07863 TORNILLO AUTOPER FORANTE 8 X 1 2 8 24072 REBORDE REMOVIBLE DEL CALENTADOR 078...

Страница 23: ...Juego de instalaci n en exteriores Juego de instalaci n en exteriores Modelos AD250 y AW250 No de pieza 24097 11 Notes...

Страница 24: ...para recibir ayuda o enviar un correo electr nico a customerservice lbwhite com Cuando llame aseg rese de que tiene el n mero de mode lo del calefactor y el n mero de configuraci n Servicio PROVEEDOR...

Отзывы: