1.
Assemble according to the illustration below and tighten
all eyebolts securely.
FIG. 2
2.
Be sure heater is securely fastened and is hanging
level. (Check crosswise and lengthwise.)
3.
See Fig. 3 for typical indoor installation. In any animal
confinement building, consideration must be given to
making sure the heater is located away from the
livestock so that livestock cannot knock the heater, tear
it loose from its mounting, or damage the heater or its
gas supply line in any way. Make sure you observe and
obey minimum clearance distances to combustible
materials as stated in the specification section of this
owner’s manual and on the heater dataplate.
FIG. 3
Assemble the tee, nipples and cap together and tighten
securely. The sediment trap assembly must always be
mounted in a vertical position. Make sure pipe thread
compound that is resistant to both L.P. and natural gas is
used in making all connections. Check all connections for
gas leaks using approved gas leak detectors.
FIG. 4
9
HANGING INSTRUCTIONS
SEDIMENT TRAP ASSEMBLY
EYEBOLT
NUT
FLAT WASHER
CAGE NUT
CHAIN
CASE TOP
OPTIONAL INDOOR
REGULATOR
MOUNTING LOCATION
GAS HOSE
THERMOSTAT
CORD
YOKE
HEATER
THERMOSTAT
30.5CM
30.5CM
BLACK PIPE
THROUGH WALL
VENT LINE
WALL OUTLET
POWER CORD
SEDIMENT
TRAP
W
ALL
CHAIN OR CABLE
NIPPLE
HOSE ADAPTER
TEE
NIPPLE
CAP
TO GAS CONTROL
VALVE INLET