Operation
Output AVB statuses
In the AVB output page, the signal status is visible in the stacked view 2 (refer to
Stacked views
(p.32)).
NOT CONNECTED
The Unit is not connected to any listener.
If unexpected, possible causes are:
• The attempted connection failed.
• An AVB controller requested a disconnection.
To resolve, connect an AVB controller and use it to connect a listener to the Unit.
WAITING REUSE
The AVB stream format has been modied by the AVB Controller, and the AVB talker
interrupted streaming for about 30 seconds to ensure that the previous stream reservations are
released in the network.
WAITING
RESERVATION
The AVB Talker of P1 is waiting for the conclusion of the bandwidth reservation from an AVB
Listener.
If displayed for more than a few seconds:
• Check the network for a disconnected cable.
• Check that the listener is in working order (fully booted).
RESERVATION
ERROR
The bandwidth reservation has failed.
It can also be temporarily displayed when a network cable is disconnected then reconnected.
If displayed for more than a few seconds, check the
List of AVB reservation errors
(p.77).
WAITING START
The bandwidth is reserved but the Unit has received a "stop streaming" command by the AVB
controller: Try disconnecting and reconnecting the stream.
READY
and the
sampling frequency
Waiting for media clock to set up.
If displayed for more than a few seconds, possible cause is: Non-Avnu certied devices on the
network are disrupting the media clock synchronization: preferably use Avnu-certied devices.
STREAMING
and the
stream format
Sending audio stream data.
36
P1 user manual (EN) version 2.1