background image

LS10

owner's manual (EN)

Содержание LS10

Страница 1: ...LS10 owner s manual EN ...

Страница 2: ... manual EN version 1 0 Distribution date April 8 2020 2020 L Acoustics All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express written consent of the publisher ...

Страница 3: ...upply 11 Inspection and preventive maintenance 12 How to do preventive maintenance 12 CHK External structure 12 CHK External cleanness 12 CHK Network functionalities and rmware 13 Installation 14 Mounting 14 Ventilation 16 General Purpose Output GPO 16 24 V DC Input and Output 17 Network cabling 19 Connection panels 19 Cabling examples 20 Connecting to AC mains 22 Electrical speci cations 22 Power...

Страница 4: ...ton 24 Using Switch Con guration Tool 25 Introduction 25 Assigning individual IP addresses to the LS10 of a network 26 Updating the LS10 rmware 30 Ethernet 32 USB 35 Speci cations 36 Appendix 39 Appendix A Glossary 39 Appendix B Approvals 40 4 ...

Страница 5: ...powering on the generator Never incorporate equipment or accessories not approved by L Acoustics Read all the related PRODUCT INFORMATION documents shipped with the products before exploiting the system Intended use This system is intended for use by trained personnel for professional applications As part of a continuous evolution of techniques and standards L Acoustics reserves the right to chang...

Страница 6: ...al injury It can also notify the user about instructions that must be strictly followed to ensure safe installation or operation of the product This symbol noti es the user about instructions that must be strictly followed to ensure proper installation or operation of the product This symbol noti es the user about complementary information or optional instructions Do not open unless authorized Thi...

Страница 7: ...nstructions and refer to the cabling schemes Installation p 14 Network cabling p 19 4 To con gure the settings and parameters of the product follow the step by step operation instructions Operation p 24 As part of a continuous evolution of techniques and standards L Acoustics reserves the right to change the speci cations of its products and the content of its documents without prior notice Check ...

Страница 8: ...cal links Two units mounted side by side on the dedicated 1U rack shelf allow to create a seamless redundant network effortlessly Upgrading LA RAK II to LA RAK II AVB is possible The rugged LS10 incorporates features designed to overcome the challenges of touring events but also installation applications The quick 5 second startup time allows for rapid recovery in case of power loss A con gurable ...

Страница 9: ...ower distribution LA PANEL II for audio and network distribution and two LS10 for AVB distribution Software applications Switch Con guration Tool Application for remote monitoring of LS10 Cables 1 6 point terminal block connector Phoenix MSTB 2 5 6 ST 1754520 Rigging elements LS10 RAKSHELF Illustrations LA Network Manager which includes Switch Con guration Tool LS10 owner s manual EN version 1 0 9...

Страница 10: ...CON I Os 1 Gb s rear side 2 SFP cages supporting 1 Gb s interfaces In addition the switch features 1 Mains power input IEC C13 V Lock compatible socket 1 6 point terminal block that gathers 1 24 V DC IN 1 24 V DC OUT pin for power supply backup GPO for status control 1 USB port for maintenance and switch con guration 10 LS10 owner s manual EN version 1 0 ...

Страница 11: ...res Ethernet ports that can operate at 10 Mbit s 100 Mbit s or 1 Gb s in half duplex or full duplex mode The operating mode and speed are automatically negotiated with the connected device The 8 ports equipped with RJ45 also feature auto MDI MDIX detection to use straight or crossover cables LS10 supports the management of up to 150 AVB streams regardless of the number of channels of these streams...

Страница 12: ...loyment touring applications or at least once a month xed installations CHK External structure p 12 CHK External cleanness p 12 Functionalities At least once a year CHK Network functionalities and rmware p 13 CHK External structure The icon indicates a visual inspection chassis is not damaged front and rear connectors are not damaged CHK External cleanness Use a dry cloth to remove any dust from t...

Страница 13: ...e cable 2 Open the Switch Con guration Tool application a Open LA Network Manager b Click Switch Con guration Tool c Scan the network 3 Check that the switch is detected by the application Refer to Using Switch Con guration Tool p 25 for more information 4 Check that all L Acoustics switches in the system run the same version of the rmware 5 If convenient update LA Network Manager and the rmware t...

Страница 14: ...AK II as well as other 19 inch racks Mounting two LS10 on LS10 RAKSHELF Tools torque screwdriver T10 Torx bit Material 6 M3 6 Torx screws There are three different mounting con gurations for LS10 on LS10 RAKSHELF side by side in front position default side by side in rear position side by side with one in inverted position Procedure 1 Turn upside down one or two LS10 and revert the LS10 RAKSHELF o...

Страница 15: ...Installation 2 Place the screws in the appropriate holes 3 Tighten the screws 1 N m T10 4 Turn back the assembly to nominal position for cabling and mounting LS10 owner s manual EN version 1 0 15 ...

Страница 16: ...r panel that includes a con gurable GPO to indicate the presence of a fault on the LS10 It can be connected with a 6 point terminal block The pitch of the connector is 5 mm GPO 6 point terminal block GPO is controlled by a Normally Open NO relay that can operate in a circuit with up to 30 V DC 1 A Relay max rating 6 point terminal block 30 V DC 1 A GPO PIN 3 PIN 4 Relay is open when the unit is un...

Страница 17: ...e backup power thanks to this cable To do so each LS10 must be connected to independent power sources This cable can be made with two Phoenix connectors reference MSTB 2 5 6 ST 1754520 for example and a cable with three conductors such as Alpha Wire reference 1896L SL005 Connectors and cable conductors are connected as follows cable conductor from PIN 1 to PIN 5 cable conductor from PIN 2 to PIN 2...

Страница 18: ...Installation External 24 V DC powering 24 V DC 10 10 W External power supply 24 V DC IN PIN 5 GND PIN 2 18 LS10 owner s manual EN version 1 0 ...

Страница 19: ...must not be less than 15 times the cable s outside diameter L Acoustics has tested the following the SFP modules Avago AFBR 5710PZ FS SFP1G SX 85 Finisar FTLF8519P3BNL USB The female micro type USB port is used for maintenance operations and for switch con guration Refer to Using Switch Con guration Tool p 25 for more information Ethernet connectors The Ethernet etherCON I Os allow to create a loc...

Страница 20: ...Installation Cabling examples Example of non redundant network with hybrid topology LA4X LA4X LA12X LS10 front rear P1 Computer Ethernet AVB Ethernet Console 20 LS10 owner s manual EN version 1 0 ...

Страница 21: ...Installation Example of redundancy topology Computer P1 LS10 front rear primary network LS10 front rear secondary network front rear LS10 owner s manual EN version 1 0 21 ...

Страница 22: ... live wires of a 100 V three phase circuit Power cord The removable IEC cord is tted with a female IEC C13 connector with V Lock at one end and a country speci c plug at the other end type plug cable ratings live neutral ground CE CEE 7 7 earthed 10 A 250 V CN GB 2099 earthed 10 A 250 V JP JIS C 8303 earthed 7 A 125 V brown blue green yellow US NEMA 5 15 earthed 10 A 125 V black white green Strict...

Страница 23: ...nother LS10 via 24 V DC it is 20 W Powering on off LS10 features one power LED indicator To power LS10 on connect the IEC cable LS10 is detected and operational in less than 5 seconds To power the switch off unplug the power cord from the mains socket LS10 owner s manual EN version 1 0 23 ...

Страница 24: ...off link not established Reset button It is possible to reset LS10 to factory default settings using the Reset button Press the RST button and hold it for seven seconds to set back the switch to factory default settings It sets back the default IP address to 192 168 1 200 the default subnet mask to 255 255 255 0 the default options of the switch It is also possible to reset LS10 with the Switch Co...

Страница 25: ... allows to con gure the connected LS10 with the following parameters display and change the IP address update the rmware to the latest version check the status of the switch and the ports customize the switch options RSTP gPTP Error Auto Recovery de ne the fault conditions to include in the GPO General Purpose Output Logic retrieve the embedded log les when required reset to factory default settin...

Страница 26: ...ure 1 Set the Network Interface Card NIC of the computer hosting LA Network Manager to 192 168 1 254 255 255 255 0 2 Connect one LS10 at a time to this NIC with an Ethernet cable 3 Open the application with LA Network Manager Click Switch Con guration Tool The application opens on the Ethernet tab 4 Select the NIC 5 Click Scan The default IP address of LS10 is 192 168 1 200 If the switch is not de...

Страница 27: ...201 Click Apply 9 On the Network tab click Disconnect 10 Repeat the above procedure until all LS10 are con gured What to do next After all LS10 are set to a unique IP address it becomes possible to interconnect them and modify their settings or proceed to their rmware update from the Switch Con guration Tool LS10 owner s manual EN version 1 0 27 ...

Страница 28: ...uration Procedure 1 Identify the IP address and the subnet mask of the network card of the computer on which LA Network Manager will be run 2 Open the application with LA Network Manager Click Switch Con guration Tool 3 Go to the USB tab 4 Click Scan to retrieve the list of serial ports on the computer Expand the list to visualize the ports detected 5 Connect LS10 to the computer with a USB cable ...

Страница 29: ...o the LS10 9 Assign a unique IP address to each LS10 on the corresponding subnet 10 Click Apply What to do next After all LS10 are set to a unique IP address it becomes possible to interconnect them and modify their settings or proceed to their rmware update via Ethernet from the Switch Con guration Tool LS10 owner s manual EN version 1 0 29 ...

Страница 30: ...pdate Procedure 1 Set the NIC of the computer hosting LA Network Manager to 192 168 1 254 255 255 255 0 2 Connect one LS10 at a time to the computer with an Ethernet cable 3 Open the application with LA Network Manager Click Switch Con guration Tool The application opens on the Ethernet tab 4 Select a network adapter 5 Click Scan 6 Select the switch 30 LS10 owner s manual EN version 1 0 ...

Страница 31: ...pen The update takes a few seconds to load The LS10 will automatically reboot and install the new rmware What to do next Wait for 20 seconds then click Scan again to detect LS10 Select the switch to read its rmware version on the right and verify that the installation succeeded LS10 owner s manual EN version 1 0 31 ...

Страница 32: ...and the LS10 pertain to the same subnet 2 Update rmware allows to update the rmware of one more LS10 that have been detected after selecting them in the central frame 3 Retrieve Embedded Logs retrieves the logs of one more LS10 that have been detected after selecting them in the central frame 4 Connect Disconnect allows to connect to one device at a time to monitor its status and de ne particular ...

Страница 33: ...the Switch Status on the top right which performs the same command as the RST reset button on the LS10 front panel Con g The Con g tab allows to con gure the device It is possible to con gure the IP address the switch options RSTP and gPTP and the GPO options IP settings It is possible to change the IP settings address netmask gateway After changing the IP address the LS10 will be disconnected Go ...

Страница 34: ...f stream interruption even for streams forwarded by copper ports In normal network topologies it is instead recommended to manually reset the switch from the Status tab when necessary The Error Auto Recovery is available from rmware 2 10 1 1 In former rmware versions this feature is grayed out GPIO Con guration The GPIO Con guration features different options to monitor and con gure the LS10 GPO p...

Страница 35: ... ports are equipped with optical modules the option is disabled If they are not automatically disabled uncheck the ports connected with optical modules The port numbers on this window correspond to the port numbers on the front and rear labels of LS10 USB When it is not possible to connect the device with Ethernet connectors it is possible to at least identify the device connected to the USB port ...

Страница 36: ...erface 1 LED for power status 1 LED for fault status Indicators 10 LEDs for link act status Button reset to factory settings Ethernet port features gPTP grandmaster capable priority selection Management RSTP enable disable Port sensing Auto negotiation Auto crossover MDI MDIX allows to use straight or cross cables Auto sensing Full or Half Duplex Gigabit is always Full Duplex Mode AVB ports 10 por...

Страница 37: ... ProAV 1 1 requirements Supported streams Number 150 Class A and B Management IP static Firmware update through Ethernet Physical data Height Width 1 7 in 8 5 in 1U 1 2U Weight 1 kg 2 2 lb Finish black Protection rating IP3x LS10 dimensions 216 mm 8 5 in 42 mm 1 7 in 133 mm 5 2 in 149 mm 5 8 in LS10 owner s manual EN version 1 0 37 ...

Страница 38: ...n 1U Rack shelf for two LS10 6 M3 6 Torx screws Weight net 1 1 kg 2 4 lb Material electrogalvanized steel LS10 RAKSHELF dimensions 437 mm 17 2 in 193 mm 7 5 in 483 mm 19 in 44 mm 1 7 in 465 mm 18 3 in 31 8 mm 1 2 in 38 LS10 owner s manual EN version 1 0 ...

Страница 39: ... Europe CHK check procedure CN China D R disassembly reassembly procedure JP Japan KR repair kit SMPS Switched Mode Power Supply power supply inside of the ampli ed controller US United States LS10 owner s manual EN version 1 0 39 ...

Страница 40: ...Appendix Approvals LS10 is compliant with the following Avnu Alliance and the Avnu design mark are registered trademarks and or service marks of Avnu Alliance 40 LS10 owner s manual EN version 1 0 ...

Страница 41: ...L Acoustics 13 rue Levacher Cintrat 91460 Marcoussis France 33 1 69 63 69 63 info l acoustics com www l acoustics com ...

Отзывы: