Installation
General Purpose I/O (GPIO)
The amplied controller's rear side features a 10-point terminal block General Purpose I/O (GPIO).
OUT
+12V
GND
GPIO
1
2
3
4 PAR
GND
ground
1
2
3
4
input or output
PAR
Connect to a chassis ground pin for PBTL bridging. Refer to
Speaker
(p.24).
chassis ground
chassis ground
OUT +12V Used to power a contact relay, 45 mA maximum.
chassis ground
GPIO can be congured using LA Network Manager. For more information, refer to the
LA Network Manager
Help.
Connecting to AC mains
Electrical specications
AC mains specications
Verify the electrical conformity and compatibility of the mains supply.
Only connect the product to an AC power outlet rated 100-240 V, 50-60 Hz, with the following current values:
100-120 V: 20 A
200-240 V: 10 A
WARNING: The product is of Class 1 construction and shall be connected to a mains socket outlet with a
protective connection to earth.
Three-phase circuit
When the product is used in a three-phase circuit, verify the electrical conformity and
compatibility of the three-phase circuit.
Verify that the three phases work, and balance the loads between the three phases.
Verify that the neutral and earth work.
Never try to emulate a 230 V circuit connecting an apparatus to two live wires of a 120 V three-phase circuit.
LA2Xi owner's manual (EN) version 1.0