L-ACOUSTICS LA 24 MANUAL Version 2.2
17/11/08 21
•
APPENDIX A
Mains voltage selection
The LA 24 is normally shipped for 230 volt AC operation but can be configured for 115 volt
AC option. To check if the amplifier is equipped with the 115/230 V option, please follow
these steps:
1.
Make sure that the LA 24 is unplugged from the mains voltage.
2.
Remove the top and bottom cover.
3.
If the four electrolytic capacitors close to the front are rated 1500uF 200VDC, the
amplifier is for 230 volt operation only
4.
If the four electrolytic capacitors close to the front are rated 2200uF 200VDC, the
amplifier has the 115/230 volt option.
5.
Locate the jumper(s) on the solder side of the circuit board close to the mains switch.
6.
To select the desired mains voltage, install the jumpers as shown in Figure 15.
7.
For 230 volt operation; use a T 15A fuse (slow blow), for 115 volt change to a T 30 A fuse
(slow blow).
8.
Replace the amplifier top and bottom cover.
9.
For 115 volt operation; stick a ”115 VAC” label on top of the 230 VAC label on the rear
panel.
Figure 15. 230 VAC or 115 VAC selection
Warning: This modification should only be made by an experienced service technician.