Connection to LA amplied controllers
Connection to LA amplied controllers
Refer to the
Amplication reference
technical bulletin for the latest information on compatibility with amplied
controllers and cabling schemes for all enclosure types.
Enclosure drive capacity per amplied controller
Make sure the total number of connected enclosures does not exceed the maximum number of enclosures per controller
(refer to the footnote).
LA2Xi
LA12X
per output
/total
per output
/ total
KS28
1 / 4 (SE), 1 / 1 (PBTL)
1 / 4
Cabling schemes for KS28 (LA2Xi)
Refer to the cabling schemes to connect the enclosures to different types of output connectors.
Refer to the
LA2Xi owner's manual
for more information on output congurations.
Terminal block output (SE)
1+
1−
+
-
+
-
2.5 mm² cables
Terminal block output (PBTL)
1+
2−
3+
4−
+
-
+
-
2.5 mm² cables
*
For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active
loudspeakers, the value corresponds to the number of sections in parallel on the output.
KS28 owner's manual (EN) version 1.0
45
Содержание KS28