G O M - 영 문
15
1.
There are two methods of heating.
First is the setting of the heating water temperature in the boiler.
After the adjusting of the heating water temperature in to the boiler, it detects
automatically that the temperature in the installation stay ad the set value.
It is necessary to set the temperature at 60~70℃ during Spring and Fall and
70~80℃ during winter.
Be careful ;
because some Country doesn
’
t permit to use this method, but impose
to use the room thermostat.
Please follows the National and the Local law and standard in force.
2.
By monitoring the indoor temperature to heat the house.
Install a room thermostat and set it to the desired temperature.
The temperature in the house will stay at the value set in the room thermostat.
The temperature in the installation will stay at the value set in the boiler.
It is necessary to set the temperature at 60~70℃ during Spring and Fall and
70~80℃ during winter.
3.
By monitoring the indoor temperature and the outdoor temperature.
Install the external sensor to the house and the room thermostat.
The temperature in the house will stay at the value set in the room thermostat.
The temperature in the installation will stay at the value automatically adjusted by the
boiler.
This value will be high with a low external temperature; will be low with a high
external temperature.
If it
’
s necessary, this relation between the temperature of the installation and the
external temperature may be adjusted in relationship to the particular kind of heating
system and of the insulation of the house.
This adjustment may be done by the authorised service man.
Please look at the paragraph in the
“
installation manual
”
.
Proper use of the room thermostat
How to set the room temperature
Содержание KDB-181 KCA
Страница 1: ......
Страница 3: ......
Страница 19: ...G O M 영 문 16 Control Panel Symbols and Functions s burner is switched on ...
Страница 33: ......
Страница 34: ...k c 영 문 30 MEMO ...