15.  PUTTING INTO OPERATION

If the cabinet has been sharply tilted while being sited or for mounting of accessories, it must be left to stand for 

at least three hours before being started to allow the lubricating oil to settle in the compressor. 

Failure to do so can cause total destruction of the compressor refrigerating system.

Check that the voltage on the identification plate is the same as that of the network. 

 

THE ELECTRICAL SUPPLY LINE TO WHICH THE REFRIGERATOR WILL HAVE TO BE 

CONNECTED IS TO BE PROTECTED BY A VERY SENSITIVE DIFFERENTIAL SWITCH 

(Rc=16A,Dc=30mA); IT IS ALSO TO BE LINKED TO THE GENERAL EARTHING PLANT. 

Earthing is necessary and compulsory by law. 

Absolutely never use reduction units, patch cords, adapters or multiple socket outlets 

to connect the counter. 

DIRECTLY connect the equipment to the mains.

 

The cable should be fully extended and located where it is unilikely to be struck, caught or stepped on, 

away from water and the other liquids and heat sources and must not be damaged.

In case of breakage of the power cable of the cabinet, it must be replaced by the manufacturer or by 

instruction it change of it. 

Follow the manufacturer’s instructions to install the unit, using qualified personnel and complying with the electrical 

regulations for the specific country.

Incorrect installation may cause injury and damage; the manufacturer is not liable for this. 

The manufacturer disclaims all responsability for any damage to people or things due to incorrect 

observance of this rule.

16.  ENERGY SAVING TIPS

• 

Install the appliance in a dry, well-ventilated room away from heat sources (radiator, cooking surface 

and so on) and in a position out of direct sunlight. 

• 

Follow the installation instructions to ensure adequate ventilation. Insufficient ventilation to the back of 

the appliance causes an increase in energy consumption and reduces cooling efficiency.

•  The internal temperature of the appliance depends on the room temperature, how often the doors are 

opened and where the appliance is placed. These factors have to be taken into account when setting the 

thermostat. Only open the doors when strictly necessary.

• 

Let hot food and drink cool down before placing them in the appliance.

• 

The positioning of the shelves in the fridge has no effect on energy efficiency.

• 

The fridge compartment light system uses a LED light, which at the same time ensures more efficient 

lighting and reduced energy consumption.

17.  OUTER CLEANING

WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING THE POWER 

PLUG BEFORE CLEANING.

For a good preservation of the cabinet’s body a periodical cleaning is necessary.

1.  EXTERNAL BODY:

 When necessary, the external body should be cleaned with a cloth and a neutral soap and 

water solution. 

 

Use also mop for cleaning under the unit and vacuum cleaner for removing dirt or dust.

2.  STAINLESS STEEL SURFACES:

 Wash with warm water and mild detergent, rinse well and dry with soft cloth. 

Avoid scouring pads etc. which will spoil the finish of the stainless steel.

3.  SURFACES IN PLASTIC MATERIAL:

 Wash with warm water and mild detergent, rinse well and dry with soft 

cloth; under no circumstances should alcohol, methylated spirits or solvents be used.

4. 

GLASS SURFACES:

  Only  use products specifically  designed for glass  cleaning;  It  is  not  advisable to  use 

ordinary water which can leave a film of calcium on the surface of the glass.

Содержание SHUFFLE KW

Страница 1: ...SHUFFLE KW USER INSTRUCTIONS READ CAREFULLY AND KEEP WITH THE CABINET N DOC UM000495 REV A 29 09 2020 ...

Страница 2: ...LE KW Manufacturer EPTA S p A Sede legale Via Mecenate 86 20138 Milano Italy Capitale 68 515 000 R E A MI 1730229 Registro delle Imprese e Cod Fiscale n 04160730968 Partita IVA 04160730968 PAGE 2 20 N DOC UM000495 ...

Страница 3: ...ect the environment but is inflammable It is therefore essential to ensure that all refrigerant pipes are not damaged before connecting the appliance to the mains supply Every 8 gr Of refrigerant the installation room must have a 1 m minimum volume The amount of refrigerant of the appliance is indicated on the rating plate of the device In the event of leakage of the refrigerant avoid using open f...

Страница 4: ...D OUT BY QUALIFIED PERSONNEL 1 ENVIRONMENTAL PROTECTION AND REQUIREMENTS FOR WASTE DISPOSAL AND TREATMENT IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2012 19 UE For reasons connected with the safeguard of the environment and in compliance with what Directive 2011 65 EC and the relevant local national laws that establish the cabinets for refrigerated pr...

Страница 5: ...plug Remove the power supply cable and eliminate it together with the plug Do not remove the drawers and various components inside the tank to make it more difficult for children to enter the refrigerated chamber of the equipment Children are forbidden from playing with the decommissioned equipment Danger of suffocation The equipment contains flammable gas inside the refrigeration circuit which mu...

Страница 6: ...ving shelves empty so as not to create turbulence wich may prejudic refrige rated air flow and cause needless energy consumption For the corect air circulation necessary to leave 4 cm free space between the product and the bottom of each internal shelf 4 TRANSPORTATION The display cabinet is contained in a specially crated package that enables transportation by the use of fork lift trucks For each...

Страница 7: ...n For each subsequent handling of the cabinet the use of the wooden platform is recommended Carefully remove the packaging taking care not to damage the components and not to throw away those that will be needed for assembly ATTENTION After unpacking check that the appliance has not suffered damage during transportation To unpack the bench proceed as follows 1 Unscrew the screws and remove the woo...

Страница 8: ...age to people animals or the product conserved in the event of Improper use of the equipment or use by unsuitable or unauthorised staff Incorrect installation or power supply not suitable for the appliance Non compliance with this manual Non compliance with the maintenance program Unauthorized modifications to the appliance Installation of non original spare parts on equipment Installation and use...

Страница 9: ...ltage V 5 Power supply frequency Hz 6 Absorbed electrical power W 7 Absorbed electrical power in defrosting W 8 Light max power W 9 Gross volume 10 Type and quantity of refrigerant 11 Climate class It is strictly forbidden to remove tamper with the plate and change or alter the data contained in it 1 2 3 4 5 6 7 8 9 10 11 11 Example of data plates 10 POSITIONING The equipment is fitted with 6 swiv...

Страница 10: ...pliers to align the doors the equipment should be arranged on a flat surface X X WRONG Never try to adjust the position of a shelf with products on it Check the shelf is stable before placing objects on it Attach the shelf supports 14 PROLONGED SWITCH OFF When the unit is not used for a long time please take note of the following procedures Unplug the unit Clean and dry the tank well Leave the gla...

Страница 11: ...e to incorrect observance of this rule 16 ENERGY SAVING TIPS Install the appliance in a dry well ventilated room away from heat sources radiator cooking surface and so on and in a position out of direct sunlight Follow the installation instructions to ensure adequate ventilation Insufficient ventilation to the back of the appliance causes an increase in energy consumption and reduces cooling effic...

Страница 12: ...he defrosting process other than those recommended by the manufacturer 20 MAINTENANCE WARNING Maintenance must be carried out by technical staff trained and enabled for intervention on the flammable refrigerants WARNING Any work carried out on the appliance by the user strictly requires the power plug being disconnected from the mains socket ATTENTION Use protective shoes and gloves during mainten...

Страница 13: ...e user Only if the average internal temperature is too cold or not cold you can increment or decrement the temperature Press the Set key in order to see on display the temperature set point Press the key or the key in order to increment or decrement the temperature set point Press the Set key in order to store the new temperature set point Internal motor fan microswitch with door open internal mot...

Страница 14: ... cable Technical support If power failure is not due to any of the above causes call the nearest after sales service immediately empty the cabinet and store the foods in coldrooms or refrigerators that may ensure their preservation temperature THE INTERNAL TEMPERATURE IS NOT COLD ENOUGH CAUSE SOLUTION AUTHORISED STAFF Check door is perfectly closed Close correctly User Make sure that the cabinet h...

Страница 15: ...od Fiscale n 04160730968 Partita IVA 04160730968 PAGE 1 5 2 0 N DOC UM000495 General description Command panel Negative Positive temperature switch Identification data plate Front glass Adjustable shelving Rear spacer Main switch Power cord Rear grid Adjustable feet Swivel wheels without brake Bumper Front grid Adjustable feet Swivel wheels with brake ...

Страница 16: ...ication Technical specification Technical specification Technical specification A A A A 1 10 B B B B 1 10 D D 1 3 0 6 3 BUMPER 0 6 1 5 1 8 30 1 33 MAX DIMENSION 16 11 11 4 11 11 78 4 CABINET 4 3 12 5 63 3 7 16 3 79 3 MAX DIMENSION 25 9 DOOR 25 9 DOOR 25 9 DOOR 25 TANK 3 2 74 2 TANK 23 2 SHELF 26 1 SHELF 23 2 SHELF 19 7 SHELF 58 8 GLASS 22 5 GLASS 76 BUMPER 27 8 CABINET 32 8 MAX DIMENSION 62 5 DOOR...

Страница 17: ...Fiscale n 04160730968 Partita IVA 04160730968 PAGE 1 7 2 0 N DOC UM000495 Technical specification External dimensions Width x depth x High inch 79 3 x 33 x 83 5 Gross volume ft3 62 82 Net volume ft3 44 78 Refrigeration Fan Defrosting Automatic Climate class 3 Temperature classifiation Negative temp L1 13 F 0 F Positive temp M1 30 F 41 F Refrigerant R290 ...

Страница 18: ...ufacturer EPTA S p A Sede legale Via Mecenate 86 20138 Milano Italy Capitale 68 515 000 R E A MI 1730229 Registro delle Imprese e Cod Fiscale n 04160730968 Partita IVA 04160730968 PAGE 1 8 2 0 N DOC UM000495 Wiring diagram ...

Страница 19: ...D F TRANSFORMER FUSE IG GENERAL SWITCH IDT POSITIVE TEMP RANGE SWITCH INV INV1 INVERTER IP IP1 IP2 EVAPORATOR MOTOR FAN SWITCH LDV INNER TANK LED LIGHT LPS LOD POWER SUPPLY MC MC1 CONDENSING MOTOR FAN MI EVAPORATOR MOTOR FAN PBD DEFROSTING PROBE PBT TEMPERATURE PROBE RMI EVAPORATOR MOTOR FAN RELAY RTI TRANSFORMER RELAY RPS HEATER POWER SUPPLY RSG DRAINAGE PIPE HEATER RT DOOR FRAME HEATER RV DOOR G...

Страница 20: ...515 000 R E A MI 1730229 Registro delle Imprese e Cod Fiscale n 04160730968 Partita IVA 04160730968 PAGE 2 0 2 0 N DOC UM000495 www kysorwarren com www eptarefrigeration com EN ISO 9001 20 100 52000877 EN ISO 14001 20 104 141373322 TÜV AUSTRIA CERT GMBH CERTIFIED For support please call 1 800 866 5596 ...

Отзывы: