background image

M74 

INTRAMUSCULAR  INJECTION 

SIMULATOR 

2-WAYS MODEL

User's  Instruction 

KYOTO KAGAKU CO.,  LTD. 

https://youtu.be/6XEbQBKK2UE

Movie Site

English Site

Содержание M74

Страница 1: ...M74 INTRAMUSCULAR INJECTION SIMULATOR 2 WAYS MODEL User s Instruction KYOTO KAGAKU CO LTD https youtu be 6XEbQBKK2UE Movie Site English Site ...

Страница 2: ...or ation or deformation of the product as well as short circuit creating a risk of fire Do not give shocks Do not wet the electric components Do not handle the power plug with wet hands No fire Do not run the system continuously over 2 hours Ink marks on the soft surface wonʼt be removable To avoid short circuit do not run the simulator set above a power receptacle Risk of fire Contact your distrib...

Страница 3: ...lpate 2 There are 3 manners of determining injection spot which are corresponding to 4 section 3 section Hochstetter s technique and Clark Points 3 When the injection needle is punctured the lamp will show the accuracy of position and depth of injection 4 When the punctured location is correct the injection liquid may be released Water 5 Since the skin of model is made a special resin it is almost...

Страница 4: ...y Product Composition Main Model 1 Display box ofaccuracy 1 9V Dry Battery 1 4 section 3 section Hochstetter s site sensor 2 each built in the main body when shipping Clark Points Injection Spot Sensor each at left and right sides Lateral position table 1 Names ofvarious portions Hochstetter 4Sec 3Sec Accuracy Display Box Back side of Accuracy display box 3 ...

Страница 5: ... the lamp at the switch will light up Replace the battery when the 9V battery lamp is not on 4 Selection ofinjection spot determination method The 4 section 3 section Hochstetter method can be selected Please change with the switch of Accuracy Display box When Clark Point determination method is used please practice by changing sensor inside the model Please refer to P5 7 Items for changing the in...

Страница 6: ......

Страница 7: ...m the bottom 0 Removing only the skin Covering with skin 2 Replacing sensor ofinjection location dismantle 4 section 3 section Hochstetter s site sensor Remove the fastener pull off the tube then the connector in sequence Clark Injection Point Sensor Remove fasteners at 2 locations pull off the tube then the connector in sequence 6 ...

Страница 8: ...vering with skin Insert connector 1 and connector 2 into the hold under but terfly bone and the location sensor shall be join with the fas tener at the bottom seat Left and right are different from each other CD As shown in the figure open the skin slightly and cover up 2 If the skin edge is rolled in pull it out put the cover turn right the scroll insert the tube put the cover 7 Connect the conne...

Страница 9: ...purpose box and in cool and dry location Information or irregularity of the product please check with your dealer or the following units D KYOTO KAGAKU CO LTD URL http www kyotokagaku com e mail rw kyoto kyotokagaku co jp Worldwide Inquiries Ordering Kyotokagaku Head Office and Factories 15 Kitanekoya cho Fushimi ku Kyoto 612 8388 JAPAN Tel 81 75 605 2510 Fax 81 75 605 2519 All American regions KV...