Kyoto Kagaku EAR II Скачать руководство пользователя страница 2

Introduction

Manufacturer’s Note

Manufacturer’s Note

Please read the instruction carefully before use.

Before Use

MW12 EAR Examination II has been developed for the training of medical professionals only. 
Any other use, or any use not in accordance with the enclosed instructions, is strongly discouraged. 
The manufacturer assume

s

 no responsibility for any accident or damage resulting from such use.

 

Should you have any questions 

regarding

 this simulator, please feel free to contact our distributor 

in your area or KYOTO KAGAKU at any time. (Our contact address is on the back cover of this 
manual)

Product Features

The New Ear 

E

xamination Simulator II is designed to acquire safe and reliable skills in the 

examination of the external acoustic meatus and tympanic membrane with a direct otoscope. The 
model warns against painful insertion. 
Skills to be learned include: safe use of an otoscope, differentiation of typical ear problems 
and earwax/foreign body removal.

1

-Warning against painful insertion with or without beep

- self-learning mode (with a beep

 and light

)

- instructor mode (silent

, light only

)

-Major 9 cases are prepared (includes 1 normal)
-Quick switching between cases
-2 sizes of ear canals (normal and stenosis)
-Anatomically correct soft ear model that allows training in straightening the auditory canal

by pulling the auricle

-Training with a real otoscope
-The manikin neck can be tilted
-Training is possible with both left and right ears

Содержание EAR II

Страница 1: ...ons Training Sessions Instruction Manual Table of Contents P 2 P 3 P 1 P 5 P 4 After Training P 6 MW12 Do not mark on the model and other components with pen nor leave printed materials contacted on surface Ink marks on the models cannot be removed Caution EARⅡ Examination Simulator Preparation ...

Страница 2: ... Ear Examination Simulator II is designed to acquire safe and reliable skills in the examination of the external acoustic meatus and tympanic membrane with a direct otoscope The model warns against painful insertion Skills to be learned include safe use of an otoscope differentiation of typical ear problems and earwax foreign body removal 1 Warning against painful insertion with or without beep se...

Страница 3: ...soft resin Please handle with the utmost care Use a specular of recommended size Size 4 Ensure the direction of the batteries Store the simulator in the case at room temperature Keep away from heat moisture and direct sunlight For cleaning wipe the mannequin with a soft cloth which has been moistened with water or alcohol After drying the manikin please dust the head with baby powder Do not insert...

Страница 4: ...r wax small toy small sponge fragments and a spoon 2 AA batteries manikin size approx 42 21 38cm 1 5kg Type of the ear is marked on the rear surface of each ear lobe Type Mark Exam Ear normal L R 1 Exam Ear stenosis L R 2 FB Ear normal L R 3 FB Ear stenosis L R 4 11391 010 accessories for MW12 4 types of ear units 1 pair each Exam Ear normal Exam Ear stenosis FB Ear normal FB Ear stenosis 1 set of...

Страница 5: ...the left side of the lid to the indents at the left side of the battery box then push the lid to close Turn on the power switch when the training session begins Please note Do not mix up the different types of ears for different trainings Examination with an otoscope Use Exam Ear s mark 1 or 2 Foreign body removal Use FB Ear s mark 3 or 4 After inserting the ears turn on power In case the ears are...

Страница 6: ...e and no warning indicator works 1 ensure that the power switch is on then if necessary 2 replace the batteries with new ones Training Sessions Training Sessions 5 The tip of the instrument is localized by sensors and harmful insertion is indicated with a beep self learning mode or lamps instructor mode Set the training mode Trouble shooting Mode change switch Power switch When the tip of the inst...

Страница 7: ...g the canal by pulling the ear lobe Remove all the simulated ear wax small toys and sponges from the FB Ear Remove the batteries from the box and store them separately For cleaning wipe the surface of the manikin and ear models with soft cloth moistened with water or alcohol Dry the manikin naturally and dust the surface with talcum powder Do not expose the manikin and accessories to high temperat...

Страница 8: ...ns Please contact manufacturer with any discrepancies in this manual or product feedback Your cooperation is greatly appreciated For inquiries and service please contact your distributor or KYOTO KAGAKU CO LTD 本社 工場 612 8388 京都市伏見区北寝小屋町15番地 TEL 075 605 2510 直通 FAX 075 605 2519 東京支店 113 0033 東京都文京区本郷三丁目26番6号 NREG本郷三丁目ビル2階 TEL 03 3817 8071 直通 FAX 03 3817 8075 3 中耳炎 粘液性 4 中耳炎 慢性穿孔性 5 中耳炎 急性化膿性 6 真珠腫 ...

Отзывы: