installed (non user serviceable) bypass diodes.
The purpose of bypass diodes is to provide a low-resistance
current path around the shaded cells
,
thereby minimizing
PV module heating and array current losses.
The PV module employs bypass diodes that have:
・
Rated Average Forward Current [I
F(AV)
]
Above
maximum system current at highest PV module
operating temperature.
・
Rated Repetitive Peak Reverse Voltage [V
RRM
]
Above
maximum system voltage at lowest PV module
operating temperature.
11. MAINTENANCE
The PV module is designed for long life and requires very
little maintenance. Under most weather conditions, normal
rainfall is sufficient to keep the module glass surface clean.
If dirt build-up becomes excessive, clean the glass surface
only with a soft cloth using mild detergent and water. USE
CAUTION WHEN CLEANING THE BACK SURFACE OF
THE PV MODULE TO AVOID PENETRATING BACK
SHEET. The PV modules that are mounted flat (0
°
tilt
angle) should be cleaned more often, as they will not "self
clean" as effectively as modules mounted at a 15
°
tilt or
greater. Once a year, check the general condition of the
wiring and check to be sure that mounting hardware is tight.
Loose connections may result in a damaged module or
array.
KYOCERA Solar Group Sales Office
KYOCERA Corporation
Corporate Solar Energy Group
6 Takeda Tobadono-cho Fushimi-ku, Kyoto 612-8501, Japan
Phone: 81-75-604-3476
Fax: 81-75-604-3475
http://www.kyocera.com/
KYOCERA Solar, Inc.
7812 East Acoma Drive, Scottsdale, AZ 85260, U.S.A.
Phone: 1-480-948-8003 or 1-800-223-9580
Fax: 1-480-483-6431
http://www.kyocerasolar.com/
KYOCERA Solar Pty Ltd.
Level 3, 6-10 Talavera Road, North Ryde NSW 2113, Australia
Phone: 61-2-9870-3946
Fax: 61-2-9888-9673
http://www.kyocerasolar.com.au/
KYOCERA Solar do Brasil Ltda.
Av. das Americas, 20007 – Bloco 2 – Salas (rooms) 105 to 108,
Rio de Janeiro, 22790-851, Brazil
Phone: 55-21-3724-3900
Fax: 55-21-3724-3911
http://www.kyocerasolar.com.br