background image

 

 

 (Page.4/11) 

    

Service Bulletin

 

Ref. No.

 

2TV-0015 (J130) 

(Service information) 

                 

<Date>  July 19, 2019

 

KYOCERA Document Solutions Inc. 

 

           For authorized KYOCERA engineers only.  

Do not distribute to non-authorized parties.

 

 

 

CONFIDENTIAL 

 

 

Procedures to attch the dust filter and filter mounting holder 

 

 
   (Estimate work time: 10min. or less)  

No 

Procedure  

Detail 

Detach the middle left cover (

a

) and lower left 

cover (

b

), and clean around the louver (

c

) of 

inner and outer side of the machine. (Refer to 
each model service manual Chapter4 
[Detaching/reattaching the lower left cover] for 
the procedures to detach the above cover.)  
 
Reattach the middle left cover (

a

) and lower left 

cover (

b

) after cleaning. 

 

Clean around the louver (

d

) at the outer side of 

the main unit with alcohol.  

 

Affix 3 pcs. double sided tape (

f

) to the filter 

mounting holder (

e

). 

  
Note: 
The double sided tape (

f

) should not run over 

the sticking area of the filter mounting holder (

e

 

 

(Figure for 40ppm printer) 

 

(Example) 

 

 

Содержание ECOSYS M6030cdn

Страница 1: ...ield measure Refer to page 3 5 for procedure 1 2 4 and 6 and after or procedure 3 1 Clean around the louver of the middle left covr and lower left cover 2 points 2 Attach the filter mounting holder No...

Страница 2: ...st filter 2 302TX94090 PARTS HOLDER FILTER SET SP 1 O Set of 2 pcs filter mounting holders 6 pcs double sided tape 3 302TX94100 PARTS TAPE FILTER FAN SET SP 1 O Set of 6 pcs double sided tape 4 302TV9...

Страница 3: ...Set of 2 pcs filter mounting holders 6 pcs double sided tape No2 Set of 6 pcs double sided tape No3 LSU drive unit No4 5 Extract from FIG 13 of P7240cdnparts list Ref No 500s are not for supply to fi...

Страница 4: ...er left cover b and clean around the louver c of inner and outer side of the machine Refer to each model service manual Chapter4 Detaching reattaching the lower left cover for the procedures to detach...

Страница 5: ...filter mounting holder h Bottom edge of the middle left cover white Horizontal Edge i of the front side of the main unit of the middle left cover Rear side louver Z left side in the figure Vertical Up...

Страница 6: ...al covers and units below Upper right cover Middle right cover Upper left cover Middle left cover 2 LSUs Primary transfer unit 4 drum units 4 developer units Refer to each model service manual Chapter...

Страница 7: ...s A B C CONFIDENTIAL No Procedure Detail 4 Release 4 hooks t at the lower sider of the LSU drive unit s in the order of 1 to 4 in the figure and detach it from the metal plate 5 Release the upper side...

Страница 8: ...left frame of the main unit Note The LSU drive unit s cannot be take out since the FFC is connected at this procedure 7 Release 4 hooks x of COVER DUCT LEFT w at the rear side of the main unit LSU cl...

Страница 9: ...No Procedure Detail 10 Pass through the FFC terminal z disconnected at Procedure 8 in between DUCT COVER INNER of the new LSU drive unit s and the edge of the drum relay PWB y Connect the FFC terminal...

Страница 10: ...eers only Do not distribute to non authorized parties A B C CONFIDENTIAL No Procedure Detail 13 Insert 2 positioning bosses F on the LSU drive unit into2 positioning holes G on the left frame of the m...

Страница 11: ...e figure Note The hook t breaks easily and so press the root of the hook Y in the figure to insert it into the hole on the metal plate 16 Connect the wire connector q of the LSU cleaning motor to YC26...