(Page.1/11)
Service Bulletin
Ref. No.
2TV-0015 (J130)
(Service information)
<Date> July 19, 2019
KYOCERA Document Solutions Inc.
For authorized KYOCERA engineers only.
Do not distribute to non-authorized parties.
A
B
C
CONFIDENTIAL
Subject:
서비스
호출
오류
C4600
에
대한
조치
(
서비스
부품으로
먼지
필터
, LSU
구동
장치
등
설정
)
Model:
l:
P7240cdn, P6235cdn, P6230cdn, P7040cdn, P6035cdn,
P6130cdn,
M6635cidn, M6630cidn, M6235cidn, M6230cidn, TASKalfa 351ci,
M6535cidn, M6530cdn, M6035cidn, M6030cdn, TASKalfa 350ci
Classification:
Field measures
timing:
At Set Up
Next Periodic Maintenance
Next Visit/Service Call
Information only
Phenomenon:
SC/Error
Paper Feeding/Conveying
Other
Image
Machine operation
Type of change:
Hardware
Firmware and Software
Information
Depending on installation environment, dust gets into the main unit through the louver at the left side of the main
unit and adheres to the LSU drive part. The LSU cleaning motor rotation torque increases and servcie call error
C4600 (LSU cleaning motor error) might occur at the LSU slit glass cleaning (executed in a specified interval)
Follow the procedures 1-4 below when the above phenomenon occurs.
[Field measure]
(Refer to
or procedure 3)
)
1. Clean around the louver of the middle left covr and lower left cover (2 points).
2. Attach the filter mounting holder (No2)to the above louver and set the dust filter (No1).
3. Check the condition of LSU drive unit (No4 or No5) and replace it if necessary.
(It is difficult to remove dust inside the LSU drive unit and it is recommended to replace the unit but not
mandatory.)
4. (Maintenance afterward) Clean the dust filter or replace it when visiting the customer. (Standard interval
to replace: 1 year) At the same time, check the condition of the the filter mounting holder secured and if
coming off, use the double sided tape set of 6 pcs. (No3) to replace the double sided tape.
[Service parts set for the field measure]
To implement the above, parts for field measure are set for service.
Parts for field measure
No. in part table
Remarks
Set of 2 pcs. dust filters
No1
Used at the 1st attachment and filter
replacement afterward
Set of 2 pcs. filter mounting h 6
pcs. double sided tape
No2
Used at the 1st attachment only
Set of 6 pcs. double sided tape
No3
Used at the maintenance after implementing
this field measure
LSU drive unit (No4, 5)
No4, 5
Used to replace if difficult to remove dust