background image

 

 

 (Page.1/11) 

    

Service Bulletin

 

Ref. No.

 

2TV-0015 (J130) 

(Service information) 

                 

<Date>  July 19, 2019

 

KYOCERA Document Solutions Inc. 

 

           For authorized KYOCERA engineers only.  

Do not distribute to non-authorized parties.

 

 

 

CONFIDENTIAL 

Subject:

 

서비스

 

호출

 

오류

 C4600

 

대한

 

조치

 (

서비스

 

부품으로

 

먼지

 

필터

, LSU 

구동

 

장치

 

 

설정

Model: 

 

 

l:

 

P7240cdn, P6235cdn, P6230cdn, P7040cdn, P6035cdn, 
P6130cdn, 
M6635cidn, M6630cidn, M6235cidn, M6230cidn, TASKalfa 351ci, 
M6535cidn, M6530cdn, M6035cidn, M6030cdn, TASKalfa 350ci 

Classification: 

Field measures 
timing: 

 At Set Up   

 Next Periodic Maintenance 

 Next Visit/Service Call

 

 

 Information only    

 

Phenomenon: 

 SC/Error        

 Paper Feeding/Conveying    

 Other 

 Image         

 Machine operation 

 

 

 

Type of change: 

 Hardware  

 Firmware and Software      

 

 Information 

 
Depending on installation environment, dust gets into the main unit through the louver at the left side of the main 
unit and adheres to the LSU drive part. The LSU cleaning motor rotation torque increases and servcie call error 
C4600 (LSU cleaning motor error) might occur at the LSU slit glass cleaning (executed in a specified interval) 

Follow the procedures 1-4 below when the above phenomenon occurs.  

 

   [Field measure]  

(Refer t

page 3-5

 for procedure 1,2,4 and  

6 and after 

or procedure 3)

 

1.  Clean around the louver of the middle left covr and lower left cover  (2 points).  
2.  Attach the filter mounting holder (No2)to the above louver and set the dust filter (No1).  
3.  Check the condition of LSU drive unit (No4 or No5) and replace it if necessary.  

(It is difficult to remove dust inside the LSU drive unit and it is recommended to replace the unit but not   
 mandatory.)  

4.  (Maintenance afterward) Clean the dust filter or replace it when visiting the customer.  (Standard interval 

to replace: 1 year)  At the same time, check the condition of the the filter mounting holder secured and if 
coming off, use the double sided tape set of 6 pcs. (No3) to replace the double sided tape. 

 
[Service parts set for the field measure]  
To implement the above, parts for field measure are set for service. 

Parts for field measure 

No. in part table 

Remarks 

Set of 2 pcs. dust filters  

No1 

Used at the 1st attachment and filter 
replacement afterward 

Set of 2 pcs. filter mounting h 6 
pcs. double sided tape 

No2 

Used at the 1st attachment only 

Set of 6 pcs. double sided tape  

No3 

Used at the maintenance after implementing 
this field measure 

LSU drive unit (No4, 5) 

No4, 5 

Used to replace if difficult to remove dust 

 
 

 

Содержание ECOSYS M6030cdn

Страница 1: ...ield measure Refer to page 3 5 for procedure 1 2 4 and 6 and after or procedure 3 1 Clean around the louver of the middle left covr and lower left cover 2 points 2 Attach the filter mounting holder No...

Страница 2: ...st filter 2 302TX94090 PARTS HOLDER FILTER SET SP 1 O Set of 2 pcs filter mounting holders 6 pcs double sided tape 3 302TX94100 PARTS TAPE FILTER FAN SET SP 1 O Set of 6 pcs double sided tape 4 302TV9...

Страница 3: ...Set of 2 pcs filter mounting holders 6 pcs double sided tape No2 Set of 6 pcs double sided tape No3 LSU drive unit No4 5 Extract from FIG 13 of P7240cdnparts list Ref No 500s are not for supply to fi...

Страница 4: ...er left cover b and clean around the louver c of inner and outer side of the machine Refer to each model service manual Chapter4 Detaching reattaching the lower left cover for the procedures to detach...

Страница 5: ...filter mounting holder h Bottom edge of the middle left cover white Horizontal Edge i of the front side of the main unit of the middle left cover Rear side louver Z left side in the figure Vertical Up...

Страница 6: ...al covers and units below Upper right cover Middle right cover Upper left cover Middle left cover 2 LSUs Primary transfer unit 4 drum units 4 developer units Refer to each model service manual Chapter...

Страница 7: ...s A B C CONFIDENTIAL No Procedure Detail 4 Release 4 hooks t at the lower sider of the LSU drive unit s in the order of 1 to 4 in the figure and detach it from the metal plate 5 Release the upper side...

Страница 8: ...left frame of the main unit Note The LSU drive unit s cannot be take out since the FFC is connected at this procedure 7 Release 4 hooks x of COVER DUCT LEFT w at the rear side of the main unit LSU cl...

Страница 9: ...No Procedure Detail 10 Pass through the FFC terminal z disconnected at Procedure 8 in between DUCT COVER INNER of the new LSU drive unit s and the edge of the drum relay PWB y Connect the FFC terminal...

Страница 10: ...eers only Do not distribute to non authorized parties A B C CONFIDENTIAL No Procedure Detail 13 Insert 2 positioning bosses F on the LSU drive unit into2 positioning holes G on the left frame of the m...

Страница 11: ...e figure Note The hook t breaks easily and so press the root of the hook Y in the figure to insert it into the hole on the metal plate 16 Connect the wire connector q of the LSU cleaning motor to YC26...