4

Preparation

Before starting up your machine, we advise you to carefully 

read through this instruction manual. Follow all instructions 

to minimize the risk of injuries when using the machine.

Prior to operation

Before starting up your machine, please check it carefully 

for any defects. If you find any, do not start up your machine 

and contact your distributor.

Especially check:

The insulation of the electric cable should be faultless 

and without any cracks. If the electric cable is damaged, it 

should be replaced by our authorized distributor.

Mains power supply connection

The following should be observed when connecting the 

machine to the electric installation:

• Check before operation that the local power supply is 

the same as the specifications on the rating label.

• This machine is equipped with universal motor with 

double insulation. It is not necessary to have earth 

connection.  

• The electric installation shall be made by a certified 

electrician.

•  It is strongly recommended that the power supply to the 

machine should include a residual current device (RCD).

•  Product protection degree:IPX5

General safety regulations and accident 

prevention

It is essential that you read the safety regulations and 

operating instructions in their entirety and follow the 

information contained therein in order to eliminate the 

possibility of an accident or potentially dangerous situation 

from occurring while working with the machine.

•  The power plug must be plugged into a properly installed 

socket. The power supply should include a residual 

current device for max. 30 mA.

• Always check the device, the mains cable and the plug 

before using the machine. Only operate the device when 

it is in good working order and has not been damaged in 

any way. Damaged parts must be immediately replaced 

by a qualified electrician.

•  Always pull the power plug out of the socket outlet before 

doing any work on the machine, before changing the 

nozzle and whenever it is not being used.

• 

Warning!

 Inadequate extension cords can be dangerous.

• If an extension cord is used, it shall be suitable for 

outdoor use, and the connection has to be kept dry. 

• Only use suitable extension cable when working 

outdoors. Extension cable must have a minimum cross-

section of 1.5 mm

2

• 

Warning!

 This device was developed to be used with 

cleaning agents supplied or recommended by the 

manufacturer. The use of any other cleaning agents or 

chemicals can negatively affect the safety of the device.

• Cable connections should be kept dry and off the 

ground. Always uncoil the extension cable completely to 

avoid heat damage to the cable.

• 

Warning!

 Do not use the device when other persons or 

animals are in the near vicinity unless they are wearing 

appropriate protective clothing.

Name of Parts:

 1. Main unit  

 2. Handle

 3.  Spray gun holder

 4. Cord hook

 5. Wheel

 6.  Wheel cover

  7.  Variable nozzle lance

 8.  Mid nozzle lance

 9. Spray gun

 10. Spray gun hose

 11.  Foam  nozzle

 12.  Water  connector

 13.  Hose  joint 

 14. Nozzle cleaning pin

 15.  Screw

 16. Water supply hose (option)

 17. Hose clamp (option)

 18.  Main  switch

 19. Safety lock button

 20.  Trigger

Carefully read and understand these instructions 

before operating this high pressure washer.
Package Contents (Fig.1)

 1. Main unit  

 2. Handle

 3.  Spray gun holder

 4. Cord hook

 5. Wheel

 6.  Wheel cover

  7.  Variable nozzle lance

 8.  Mid nozzle lance

 9. Spray gun

 10. Spray gun hose

 (5m)

11. Foam nozzle

 12.  Water  connector

 13.  Hose  joint 

 14. Nozzle cleaning pin

 15.  Screw

Technical data

Power rating input

1,400 W

Rated pressure

70 bar (7 MPa)

Allowable pressure 

100 bar (10 MPa)

Rated flow

5.5 L / min

Max. inlet water pressure 

0.7 MPa

Max. temperature: 

40°C

Adding water    

From a faucet 

    

 

Weight  

4.5 Kg

Sound pressure level

Uncertainty

LpA=77dB(A)

KPA=3dB

Sound power level

LwA=92dB(A)

Vibration Value

aH=1.8m/s

2

Kah=0.05m/s

2

 21.  Power  cord

 22.  Filter

 23.  Hook 

 24.  Hook

 25.  Water  inlet

 26.  Release  button

 27.  Release  button

 28. Self-priming kit (option)

 29. Self-priming filter (option)

 30. Self-priming hose (option)

 31. Strainer (option)

 32. Filter cap (option)

 33.  Filter  (option)

 34. Rubber seal (option)

 35.  Rubber  seal

 36.  Ring  (option)

 37. Filter case (option)

Содержание AJP-1100

Страница 1: ...69801122 00 STD 01 22 AJP 1100...

Страница 2: ...1 1 1 2 7 8 9 11 12 13 14 3 4 10 5 6 15 2 15 4 24 3 23 5 6 7 8 9 9 10 10 5 2 3 6 4 7 8...

Страница 3: ...2 9 10 11 13 12 14 17 16 15 19 18 A B 17 16 B A 13 16 20 18 12 16 13 19 9 10 27 10 26 12 25 29 30 31 30 31 29 28...

Страница 4: ...3 20 21 22 24 23 25 28 27 26 31 32 30 29 14 7 22 12 25 9 11 7 21 25 tighten loosen 29 34 32 33 35 30 tighten loosen 29 36 tighten loosen 31 30 30 31 30 31 37 tighten 33 32 34 32 37...

Страница 5: ...never it is not being used Warning Inadequate extension cords can be dangerous If an extension cord is used it shall be suitable for outdoor use and the connection has to be kept dry Only use suitable...

Страница 6: ...a hazard Never use the machine in an environment where there could be a danger of explosion If any doubt arises please contact our authorized distributor It is not allowed to clean asbestos containin...

Страница 7: ...ressed Nozzle Lance Fig 15 Changing the spray diffusion narrow wide Change the spray diffusion by turning the end of the variable nozzle lance clockwise for narrow spray diffusion and counterclockwise...

Страница 8: ...elf priming filter 29 into water inlet by turning clockwise note Tighten Self priming filter straight onto the water inlet by turning it in a clockwise direction If the filter is not tighten correctly...

Страница 9: ...ove the filter cap and take out the filter from the filter case 2 Remove dust on the mesh of filter 3 Restore the filter and close the filter cap note Please be careful not to lose the rubber seals se...

Страница 10: ...The seals are worn The filter is clogged Change the nozzle Check clean replace Check and or replace Check and or replace Check and or clean There is excess noise Air is being drawn in The valves are...

Страница 11: ...10...

Страница 12: ......

Отзывы: