background image

KYOCERA Corporation 

 

SERIES 6809 INSTRUCTION MANUAL 

SPEC No.205-03-299  

106-03-004 

 

PAGE 

7/10

 

 

 
※FPC

/FFC

はカードスロット底面に当たるまで垂直に挿入してください。 

  Insert the FPC

/FFC

 vertically until hits the slot end. 

 

 

 

OK 

NG 

NG 

Содержание 6809 Series

Страница 1: ...106 03 003 DIV 04 SPEC NUMBER 205 03 299 OPERATION MANUAL SERIES 6809 0 5mm PITCH FPC CONNECTOR O EDN 271 6 10 15 Y Manba Y Fjii NO EDN DCN DATE PREPARED CHECK APPROVED...

Страница 2: ...ABLE OF CONTENTS 1 OUTLINE 2 2 6809 SERIES 6809 NAME OF EACH PART 2 3 PRECAUTIONS IN HANDLING 3 3 1 MOUNTING ON THE BOARD 3 3 2 OPERATION OF THE ACTUATOR 3 3 3 FPC FFC INSERTION OF FPC FFC 4 3 4 FPC F...

Страница 3: ...e touch locking type lower contact type connector with 0 5mm pitch for FPC designed to meet the market requirements of downsizing and high density package in equipment Care should be taken when handli...

Страница 4: ...o not open close the actuator of any connector before mounted or the connector may be deformed 3 2 OPERATION OF THE ACTUATOR Please do not operate one side of the actuator when opening it Lift the act...

Страница 5: ...S 6809 INSTRUCTION MANUAL SPEC No 205 03 299 106 03 004 PAGE 4 10 Please do not over open the actuator when opening it Please do not operate by hooking the claw to the actuator Please do not push the...

Страница 6: ...e connector as shown left Insert the FPC FFC with conductor side contacting side faced down and push the FPC to the point where it hits the card slot of connector FPC FFC Please do not insert an FPC F...

Страница 7: ...nter part of the actuator with soft pressure applied in the direction of the rotation axis Make sure that the FPC FFC is not inserted obliquely Please do not operate one side of the actuator when open...

Страница 8: ...KYOCERA Corporation SERIES 6809 INSTRUCTION MANUAL SPEC No 205 03 299 106 03 004 PAGE 7 10 FPC FFC Insert the FPC FFC vertically until hits the slot end OK NG NG...

Страница 9: ...ION MANUAL SPEC No 205 03 299 106 03 004 PAGE 8 10 3 4 FPC FFC PULLING OUT FPC FFC Lift up the center part of actuator Please do not operate by hooking the claw to the actuator Please do not operate o...

Страница 10: ...TRUCTION MANUAL SPEC No 205 03 299 106 03 004 PAGE 9 10 FPC FFC FPC FFC Please have pulled out parallel to the connector FPC FFC FPC FFC Please do not pull out FPC FFC with the actuator locked The con...

Страница 11: ...We will conduct evaluation tests according to conditions 4 OTHER CAUTIONS Do not throw products or apply large shock to them though contact tails and anchor plate are protected in the embossed tape wh...

Отзывы: