Mounting
8
Caution:
As part of the heat dissipation system, the switch housing becomes hot during operation.
Please use caution when coming in contact and avoid covering the switch housing when the
switch is running.
The figures in this manual are only for reference.
3.2 Mounting Modes and Steps
The series switches support DIN-rail and panel mounting. Before installation, make sure that
the following requirements are met.
1) Environment: temperature (-40
℃
to 75
℃
), ambient relative humidity (5% to 95%,
non-condensing)
2) Power requirement: The power input is within the voltage range of the switch.
3) Grounding resistance: <5
4) No direct sunlight, distant from heat source and areas with strong electromagnetic
interference.
3.2.1 Mounting
DIN-Rail Mounting
Step 1: Select the mounting position for the device and guarantee adequate space and heat
dissipation .
Step 2: Insert the connecting seat onto the top of the DIN rail, and push the bottom of the
device inward and upward to ensure the DIN rail fits in the connecting seat. Make
sure the device is firmly installed on the DIN rail, as shown in the following figure.