Access
22
NOTE:
To confirm the communication port in use, right-click [My Computer] and select [Property]. Click
[Hardw
are] → [Device Manager] → [Port] to view the communication port.
Step 5: Set port parameters (Bits per second: 115200, Data bits: 8, Parity: None, Stop bits: 1,
and Flow control: None), as shown in the following figure.
Figure 20
端口设置
Step 6: Click OK to enter the switch CLI. Then you can run the commands in Table 10 to
perform operations.
7.2 Access through Telnet
Step 1: Connect the network port of a PC to the Ethernet port of the switch with a network
cable.
Step 2: Enter "telnet
IP address
" in the Run dialog box. For example, if the IP address of the
switch is 192.168.0.2 (default IP address of a Kyland switch), enter "telnet
192.168.0.2" in the dialog box.