Connection
15
PWR1
PWR2
+/L -/N
-/N +/L
1 2 3 4 5
4.4 Power Terminal Block
You need to connect the power wires to the terminal block to provide
power to the device. The device supports single (PWR1) and redun-
dant (PWR1 and PWR2) power supply with a 5-pin 5.08mm-spacing
plug-in terminal block. When the redundant power supply is used and
one power input is faulty, the device can continue operating properly,
thereby improving network reliability.
The following figure shows the 5-pin 5.08mm-spacing plug-in terminal
block.
ƽ
5-Pin 5.08mm-Spacing Plug-in Terminal Block
Figure 15 5-Pin 5.08mm-Spacing Plug-in Terminal Block (socket)
Note:
0.75mm
2
<Cross-sectional area of the power wire<2.5mm
2
;
grounding resistance<5
Ω
.
Содержание KIEN1008BA Series