MDI/MDI-X connection. It can be connected by straight-through/cross-over
cable to terminal devices, servers, hubs or other switches. Each port
supports IEEE802.3x, so the optimum transmission mode (half-duplex or
full-duplex) and data rate (10 Mbps or 100Mbps) will be selected
automatically (the connected devices should supports this features too). If
the connected devices are not adaptive, the port will send at the correct
rate but with default mode of half-duplex.
Power Input Terminal
The KIEN1005 uses the DC24V power supply. It uses the 3.81
㎜
gap
3-wire phoenix terminal to connect to the power supply. The diameter of
the power supply is less than 1.5
㎜
.
The sequence of the connection is shown in Figureure.3-6. The connection
wire and the installation step as follows:
Peel off the crust of the power cable for about 5mm to twist several of
exposed copper wires into one bundle;
1
.
Use the 2.5mm “-“ shape screw driver to loose the “power cable lock
screw, insert the power cable into the hole at the end of the terminal,
screw tightly the “power cable lock screw”;
2
.
Insert the power supply terminal into the DC socket of the equipment,
use the 2.5mm “-“ shape screwdriver to screw tightly two “terminal lock
screw” to fixedly connect the terminal and the power supply connector.