Connection
23
power wires to the terminal block to provide power to the device. The device supports
redundant power input with a 5-pin 5.08mm-spacing plug-in terminal block. When one power
input is faulty, the device can continue operating properly, thereby improving network
reliability.
Note
:
0.75mm
2
<Cross-sectional area of the power wire<2.5mm
2
; grounding resistance<5
.
Use copper conductors only, temperature rating 75
℃
only.
Seuls les fils en cuivre sont utilisés et la température n 'est que de 75 °C.
5-Pin 5.08mm-Spacing Plug-in Terminal Block
Figure 28 5-Pin 5.08mm-Spacing Plug-in Terminal Block (socket)
Table 9 Pin Definitions of 5-Pin 5.08mm-Spacing Plug-in Terminal Block
No.
Signal
DC Definition
AC Definition
1
+/L
PWR1: +
PWR1: L
2
-/N
PWR1: -
PWR1: N
3
PGND
PGND
4
-/N
PWR2: -
PWR2: N
5
+/L
PWR2: +
PWR2: L
Wiring and Mounting
Step 1: Ground the device properly according to section 4.5.
Step 2: Remove the power terminal block from the device.
Step 3: Insert the power wires into the power terminal block according to Table 8
and secure the wires.
Step 4: Insert the terminal block with the connected wires into the terminal block socket on