background image

 

 

 

 

SICOM2024M Industrial Ethernet Switch 

Hardware Installation Manual 

 

 

 

 

 

 

Kyland Technology Co., Ltd. 

 

Publication Date:

 

Sep. 2013 

Version: V4.3 

FAX: +86-10-88796678 

Website: http://www.kyland.com 

E-mail: 

[email protected]

 

 

 

Содержание SICOM2024M-16T

Страница 1: ...COM2024M Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co Ltd Publication Date Sep 2013 Version V4 3 FAX 86 10 88796678 Website http www kyland com E mail support kyland co...

Страница 2: ...ated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reprod...

Страница 3: ...istatic gloves or take other protective measures when operating the device Avoid any exposed metal wires because they may be oxidized or electrified Install the device in accordance with related natio...

Страница 4: ...reventing environmental pollution In the following cases please immediately shut down your power supply and contact your Kyland representative Water gets into the equipment Equipment damage or shell d...

Страница 5: ...s and Steps 8 4 Connection 11 4 1 10 100Base T X Ethernet Port 11 4 2 100Base FX Ethernet Port 12 4 3 Console Port 13 4 4 Grounding 13 4 5 Power Terminal Block 14 4 6 Alarm Terminal Block 16 5 LEDs 18...

Страница 6: ...n of the system SICOM2024M provides powerful network management functions The device can be managed through CLI Telnet Web and SNMP based network management software SICOM2024M supports 19 inch 1U rac...

Страница 7: ...Table 2 Description of Front Panel 1 No Identifier Description 1 ALARM Alarm LED 2 RUN Running LED 3 PWR1 Power 1 LED 4 PWR2 Power 2 LED 5 G1 G4 DPX Speed LEDs for four 100Base FX Ethernet ports 6 G1...

Страница 8: ...Ds for two 100Base FX Ethernet ports 5 A B Link ACT Connection status LEDs for two 100Base FX Ethernet ports 6 1 24 Link ACT Connection status LEDs for twenty four 10 100Base T X Ethernet ports 7 1 24...

Страница 9: ...the front panel 8 100Base FX Ethernet port Its status is indicated by G3 on the front panel 9 100Base FX Ethernet port Its status is indicated by G4 on the front panel 10 Grounding screw 11 Power ter...

Страница 10: ...w 9 Power terminal block 10 PWR1 PWR2 ON OFF Switches for Power 1 and Power 2 Figure 5 Rear Panel of SICOM2024M 2S M 24T and SICOM2024M 1S M 24T Table 6 Description of Rear Panel of SICOM2024M 2S M 24...

Страница 11: ...M2024M 24T Table 7 Description of Rear Panel 1 of SICOM2024M 24T No Identifier Description 1 1 24 Twenty four 10 100Base T X Ethernet ports 2 10 100Base T X Ethernet port speed LED 3 10 100Base T X Et...

Страница 12: ...ng screw 7 Power terminal block 8 P1 P2 ON OFF Switches for Power 1 and Power 2 Rear Panel of SICOM2024M 16T Figure 8 Rear Panel of SICOM2024M 16T Table 9 Description of Rear Panel of SICOM2024M 16T N...

Страница 13: ...mes hot during operation Please use caution when coming in contact and avoid covering the switch housing when the switch is running The figures in this manual are only for reference 3 2Mounting Modes...

Страница 14: ...source and areas with strong electromagnetic interference Installing Mounting Brackets Figure 10 Mounting Bracket You can select the screw holes for front or rear panel mounting to install the mountin...

Страница 15: ...ith the corresponding holes in the rack posts Then use four screws and supporting captive nuts to secure the mounting brackets to the rack posts Figure 12 Mounting Dismounting Step 1 Remove the four s...

Страница 16: ...r network device with a straight through or cross over cable Pin Definition The following figure shows the pin numbers of the RJ45 port 8 7 6 5 4 3 2 1 Figure 13 RJ45 Port The following table lists th...

Страница 17: ...port and RX receive port To enable data transmission between Device A and Device B connect the TX port of Device A to the RX port of Device B and the RX port of Device A to the TX port of Device B The...

Страница 18: ...able One end of an RJ45 DB9 console cable is crimped RJ45 connector to be inserted into the console port of the switch and the other end is the DB9 connector to be inserted into the 9 pin serial port...

Страница 19: ...Power Terminal Block There is a power terminal block on the rear panel of the device You need to connect the power wires to the terminal block to provide power for the device The device supports both...

Страница 20: ...ting Step 1 Ground the device properly according to section 4 4 Step 2 Remove the power terminal block from the device Step 3 Insert the power wires into the power terminal block according to Table 12...

Страница 21: ...inal or component with a voltage warning sign because it may cause damage to humans Do not remove any part or plug in or out any connector when the device is powered on 4 6Alarm Terminal Block The dev...

Страница 22: ...tacts pin 2 and pin 3 are normally closed contacts When the switch works properly pin 1 and pin 2 are closed pin 2 and pin 3 are open when an alarm occurs pin 1 and pin 2 are open pin 2 and pin 3 are...

Страница 23: ...device is starting up Alarm LED On An alarm occurs Off No alarm occurs 100Base FX Ethernet port speed LED On 100M working state 100Base FX Off No connection 100Base FX Ethernet port connection status...

Страница 24: ...or no connection 10 100Base T X Ethernet port connection status LED green On Effective port connection Blinking Ongoing network activities Off No effective port connection 100Base FX Ethernet port co...

Страница 25: ...pin serial port of a PC with the delivered RJ45 DB9 console cable Step 2 Open the Hyper Terminal in the Windows OS On the desktop click Start All Programs Accessories Communications Hyper Terminal Ste...

Страница 26: ...mmunication port in use right click My Computer and select Property Click Hardware Device Manager Port to view the communication port Step 5 Set port parameters Bits per second 9600 Data bits 8 Parity...

Страница 27: ...ss Management view SWITCH config terminal Enter the configuration view 6 2Access through Telnet Step 1 Connect the network port of the PC to the RJ45 port of the switch with an RJ45 RJ45 cable Step 2...

Страница 28: ...d You can log in to the Web UI by default user name admin and password 123 Note IE8 0 or a later version is recommended For details about how to access the switch and other operations refer to the Web...

Страница 29: ...5 08mm spacing plug in terminal block Rated Power Consumption Rated power consumption 16 8W Physical Characteristics Housing Metal fanless Installation 19 inch 1U rack mounting Dimensions W H D 440mm...