Shenzhen KYL Communication Equipment Co., Ltd
Fax: +86-755-83408785 [email protected] www.rf-data.com
10
any response. If those address codes are the same, it means the data is sent to the
local. Slave station will make different responses according to the transmitted data
or command and send back the data of response. All these jobs must be performed
by upper protocol, and it is assured that there is only one transmitter-receiver in the
state of transmission in the communication network at any instant moment so as to
avoid the cross-interference.
KYL-500L can also be used for point-to-point communication with easier operation.
For the programming of serial port, all you have to do is to remember that its
communication mode is semi duplex while always observing the time sequence of
come-and-go for receiving and transmitting.
VI. Technical specification of KYL-500L
* Modulation mode: GFSK/FSK
* Working frequency: 400MHz~470MHz
* Power supply: DC 3.3-3.6V
(
±10%
)
* RF power:
≤
400 mW;
* RF data rate: 1200/2400/4800/9600/19200bps (Set before delivery);
* Receive current: <25mA (TTL connect);
* Receive sensitivity: -123dBm (1200bps); -118dBm (9600bps);
* Transmitting current: <400mA;
* Sleep current: <1uA;
* Interface data format: 8E1/8N1/8O1;
* Working temperature: -40
~+
80
(industrial
standard)
* RF Line-of-sight Range: 1.5km (BER=10-5@9600bps);
2km(BER=10-5@1200bps)
;
* Size: 49mm*23mm*10mm (without antenna port).
VII. Description of type
KYL-500L-96
Manufacture
Type
Baud Rate
12:1200bps
24:2400bps
48:4800bps
96:9600bps
192:19200bps