KYL KYL-300M Скачать руководство пользователя страница 4

Shenzhen KYL Communication Equipment Co., Ltd

Fax: +86-755-83408785             

[email protected]

             

www.rf-data.com

4

1. Power supply

The  factory  default  setting  is  +5V  (7.5V-12V  will  inform  when  placing  the 
order).By using better ripple factor, KYL-300M transceivers can also share power 
supply with other equipment. If possible, a voltage-stabilizing chip with 5V voltage 
is more recommended as the only power supply than Switch power supply. But if 
only  switch  power  supply  available,  the  jam  by  switch  pulse  to  the  transceivers 
should be avoided. In addition, the reliable grounding must be used if there is other 
device in the system equipment. In case of failing to connect with the ground, it can 
form  its  own  grounding  but  must  be  absolutely  separated  from  the  municipal 
electric supply.

2. 

Connection Definition with terminal

KYL-300M transceivers  supply  one  9-pin  connector  (JP1),  their  definitions  and 
connection methods with terminals are shown in Table 1.

Table 1: JP1 Pin Definitions and connection methods

Pin No. Signal Name Function

Level

Connection 
with terminal

Remarks

1

GND

Grounding of power supply

Ground

2

Vcc

Power supply DC

5V

3

RxD/TTL

Serial data input to the transceiver

TTL

TxD

4

TxD/TTL

Transmitted 

data 

out 

of 

the 

transceiver

TTL

RxD

5

SGND

Signal

6

A (TXD)

A of RS-485(TxD of RS-232)

A(RxD)

7

B (RXD)

B of RS-485(RxD of RS-232)

B(TxD)

8

SLEEP

Sleep control (input)

TTL

Sleep signal

High 

level 

sleep

9

RESET

Reset signal(input)

TTL

Negative 
pulse reset

3. The connection schematic diagram between computer and our
RF module

Содержание KYL-300M

Страница 1: ...nzhen KYL Communication Equipment Co Ltd Address C3705 3707 Huangdu Square South of Exhibition Center Yitian Road Futian District Shenzhen Guangdong China 518048 Tel 86 755 82943662 Fax 86 755 8340878...

Страница 2: ...transmission distance is 7km 1200bps and is 5km 9600bps respectively 5 Transparent data transmission Transparent data interface used in transceivers is to meet many standard and nonstandard user proto...

Страница 3: ...larm and security systems Building automation security wireless monitor and control of room equipment Access Control System Wireless data transmission automatic data collection system Radio modem can...

Страница 4: ...ith the ground it can form its own grounding but must be absolutely separated from the municipal electric supply 2 Connection Definition with terminal KYL 300M transceivers supply one 9 pin connector...

Страница 5: ...can change or view the module s interface baud rate channel and address code Parameter setting or reading as per the testing software KYLCOM in the PC in products box And the configuration is as follo...

Страница 6: ...ucing more consumption KYL 300M transceivers support Sleep function In sleep mode the current consumption is less than 20uA a How to use the Sleep function The Pin8 SLP in JP1 is the signal of sleep c...

Страница 7: ...o the first bit received by RxD Due to a data processing will be made on user s data by KYL 300M transceiver using FEC Forward Error Correction or other correction algorithm when RxD of a KYL 300M tra...

Страница 8: ...ng as below What if the actual transmission BER Bit Error Rate is 10 4 1 packet with 1KB data which is about 10 thousand bits is sent theoretically at least 1 bit will be received wrongly then the 1KB...

Страница 9: ...ease browse our website http www kylcom com Products_list_en asp classid 163 If the user has special demands on antennas we can design and produce for them specially V Networking Application of KYL 30...

Страница 10: ...ll you have to do is to remember that its communication mode is semi duplex while always observing the time sequence of come and go for receiving and transmitting VI Technical specification of KYL 300...

Отзывы: