4. Use guide
4.1
Application scenarios
1. Pv array tilt less than 20° (dry brush) or 10° (wash)。
2. The nadir of the photovoltaic array is more than 10cm.
3. The edge of the photovoltaic array is free of obstacles within a 50cm range.(If only the top is obstructed, you can use
a custom limit on the number of rows to do not clean the top row )
4. The PV arrays are spaced less than 4cm apart.
5. The height difference of photovoltaic modules is less than 4cm.
6. There are white gaps between the photovoltaic modules' cells.
7. The supported types of photovoltaic panel are as follows:
Main grid line(BB)
Type
Size(mm)
PCS
2BB
Full size
156
60
3BB
Half size/Full size
156/158
60/72
4BB
Half size/Full size
156/158
60/72
5BB
Half size/Full size
156/158
60/72
6BB
Half size/Full size
156/158
60/72
MBB
Half size
162/166/182/210 60/72
The interval between PV array is less than 4cm
The height difference is less than 4cm
<20°
The lowest point of the PV panel suspension is greater than 10cm
Obstacles such as walls and pipes should be within 50cm of the
top edge of photovoltaic array
* In the case of self-identification, MBB default M6/166mm size, which can be customized.
* At a singular scenario, you are advised to customize the scenario mode.
6
*
Due to the needs of continuous improvement of the product, this material product is subject to the physical, our company reserves the right to update the product.
* Safety protection devices such as guardrail and protective shed should be built around the photovoltaic array to prevent safety accidents.
* When the product is operated at the height above 2m (including 2m), which is likely to fall, it should follow the Technical Specification for Safety of Operation at High Places in Construction.
There are no obstacles within 50cm of photovoltaic array edge