KW Hydraulik Dynaset WHU110/200-12VDC Скачать руководство пользователя страница 3

3

Water heating unit WHU110/200 -12V_24V

MAY CHANGE WITHOUT PRIOR NOTICE 

WARNING STICKER

Dynaset dispatch department includes one (1) warning sticker bag per one (1) main product. 
Product recipient is obligated to fix determinate warning sticker to Dynaset product. 
Fix sticker to visible and appropriate place or close to Dynaset product where it’s easily seen. 
Before fixing sticker clean surface with solvent detergent. 

READ OPERATION INSTRUCTIONS.  RISK OF ELECTRIC SHOCK.  BEWARE OF HOT SURFACE.

SAFETY PRECAUTIONS

The hydraulic system is usually pressurized up to 250 bar.  
In order to avoid 

damages and 

accidents operator and maintenance personal must act in compliance with the 

laws, regulations and recommendations issued by local electricity and work safety authorities.   

Follow all your local safety instructions related to electric devices and the high-pressure hydraulics.

TECHNICAL CONDITION OF YOUR MACHINERY AND EQUIPMENT MUST BE SUBJECT TO CONSTANT 
SURVEILLANCE. 

Hydraulic system of a carrier machine should be maintained according to the service program.

All couplings, valves and hoses should be maintained tight and clean as well as kept under constant 
observation.
Leaks in the hydraulic system must be fixed immediately to avoid injuries caused by high pressure and oil 
blowouts.

 

Prior to maintenance, detaching from a carrier or disassembling a DYNASET-unit, the hydraulic system of a 
carrier machine should be stopped and DYNASET’s hydraulic circuit depressurized.

When operating or maintaining in the immediate vicinity of DYNASET hydraulic unit or accessories, appropriate 
protective clothing, safety goggles, gloves, ear and eye protection should be worn. 
Do not touch parts heated by hydraulic oil.            

EXTERME CLEANLINESS MUST BE MAINTAINED WHEN CARRYING OUT ANY SERVICE 
DISSASSEMBLING OR REPAIR OF UNIT AND HYDRAULIC SYSTEM.  THIS IS CRUCIAL TO ENSURE 
SAFE, RELIABLE AND LONG-LIFE OPERATION OF YOUR EQUIPMENT.

Prevent freezing nozzles, water circuit and pipeline. Draining and air flushing have to perform before 

ambient temperature reaches 0°C (32°F).

Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.  
Engines give off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide can cause 
nausea, fainting or death. 
Unintentional sparkling can result in fire or electric shock. Unintentional start-up can result in entanglement, 
traumatic amputation, or laceration. See appendix engine manual.  

All installation and service of both hydraulic and electric equipment must be performing experienced personnel 
only. 

November 2014 JLe

Содержание Dynaset WHU110/200-12VDC

Страница 1: ...vember 2014 JLe Water heating unit WHU110 200 12V_24V WHU110 200 12_24VDC WATER HEATER UNIT MAY CHANGE WITHOUT PRIOR NOTICE OPERATING INSTRUCTIONS Note This manual is valid from WHU serial number 4156...

Страница 2: ...5 2 Startup sequence 7 5 3 Switch off sequence 7 6 INSTALLATION AND OPERATION 8 7 MAIN ASSEMBLY 9 8 PART LIST 10 9 WIRING DIAGRAM WHU110 200_12V 11 10 WIRING DIAGRAM WHU110 200_24V 12 11 WHU 110 200 1...

Страница 3: ...em must be fixed immediately to avoid injuries caused by high pressure and oil blowouts Prior to maintenance detaching from a carrier or disassembling a DYNASET unit the hydraulic system of a carrier...

Страница 4: ...ring capacity The unit is to be connected to pressure line of Dynaset HPW high pressure pump Unit is especially intended for mobile use It has next connections Water tank hot water out and electric po...

Страница 5: ...3 R 1 2 R 1 2 R 3 8 OUTLINE DIMENSIONS AND CONNECTIONS 3 1 2 A Water heating unit WHU110 200 12V_24V MAY CHANGE WITHOUT PRIOR NOTICE FOOT 3 1 INSTALLATION DIMENSIONS WATER PORTS INSTALLATION DIMENSIO...

Страница 6: ...3 B Exhaust gas temperature 300C Alarm 4 C Exhaust gas temperature drops more than 15 C after burning sequence has started Alarm 2 if ignition sequence has failed Alarm 1 or if emergency stop button h...

Страница 7: ...tton for 2 seconds until failure indicator light will go off STARTUP SEQUENCE Heater cuts the fuel flow if determinate temperature has reached and performs exhaust gas ventilation 10 sec Water runs no...

Страница 8: ...ynaset HPW pump pumping water to the WHU unit If the water system has mixing valve between WHU supply and outlet lines it is possible to adjust water temperature accordingly 4 Switch WHU main switch o...

Страница 9: ...MAIN ASSEMBLY 1 1 2 0 2 7 2 6 2 11 3 1 3 2 3 3 3 5 3 11 Water heating unit WHU110 200 12V_24V 9 MAY CHANGE WITHOUT PRIOR NOTICE November 2014 JLe 2 14...

Страница 10: ...NTING RAIL EN 35x7 5mm 1 2 29 8500056500 ALLEN SCREW M6x25 8 8 2 2 30 8500880700 NUT M6 2 2 31 8501200500 LOCKING WASHER A6 4x11 4 2 32 8500403800 ALLEN SCREW M4X35 8 8 2 2 33 8501710910 SCREW COUNTER...

Страница 11: ...WHU110 200 12V WIRING DIAGRAM MAY CHANGE WITHOUT PRIOR NOTICE Water heating unit WHU110 200 12V_24V 11 November 2014 JLe...

Страница 12: ...WHU110 200 24V WIRING DIAGRAM MAY CHANGE WITHOUT PRIOR NOTICE Water heating unit WHU110 200 12V_24V 12 November 2014 JLe...

Страница 13: ...18 5 4 2 19 25 22 15 26 23 9 28 27 16 34 17 35 32 29 33 13 1 DETAILS MAY CHANGE WITHOUT PRIOR NOTICE WATER HEATING UNIT WHU 110 200 12V_24V BURNER ASSEMBLY 11 2014 Water heating unit WHU110 200 12V_2...

Страница 14: ...1500 1 14 BOILER 1 15 ELECTRIC MOTOR 12V 1 16 PUMP 1 17 CONNECTION 1 18 SELF TAPPING SCREW 3 5X10 AB 3 19 SELF TAPPING SCREW 3 5X14 AB 3 20 SELF TAPPING SCREW 3 9X13 AB 5 21 SELF TAPPING SCREW TSP 5X7...

Страница 15: ...TION DETAILS QUANTITY NUMBER 1 FERRULE 4 2 COVER 1 3 INSULATOR 1 4 COVER 1 5 JACKET 1 6 INTERNAL JACKET 30L 1 7 COIL 30L 1 8 CLAMP 1 9 WASHER M20 UNI6592 4 10 INSERT UNI 9202 A M61 4 WHU 110 200 12V_2...

Страница 16: ...LE G1 4 1 5 FLANGE 1 6 FLANGE 1 7 GLASS 1 8 GLASS 19 1 9 DEFLECTOR WORK 1 10 ELECTRODES 1 11 CONNECTION 1 12 SCREW M5X10 UNI5931 1 13 SCREW M5X12 UNI7687 2 14 SELF TAPPING SCREW 3 9X13 2 15 O RING 013...

Страница 17: ...RIOR NOTICE No STOCK DESIGNATION DETAILS QUANTITY NUMBER 1 FLANGE 1 2 ELECTRIC MOTOR 12V DC 500W 2800 rpm 1 3 SCREW M6X16 UNI5933 1 WHU 110 200 12V_24V ELECTRIC MOTOR ASSEMBLY Water heating unit WHU11...

Страница 18: ...management facility if not Separating the base materials iron copper steel electronics removing paint polyester resin and insulation tape and or plastics residues from all components This waste materi...

Страница 19: ...DYNASET OY or authorized workshop all costs excluded from this warranty traveling and waiting hours daily allowance traveling expenses and uninstallation reinstallation costs will be charged from the...

Страница 20: ...010 Hydraulic fluid power General rules and safety requirements for systems and their components Safety of Machinery Electrical equipment of machines SFS 60204 SFS EN 60204 1 6 Protection against elec...