8. CABLE REQUIREMENTS
Pin
Color
1
Orange
/White
2
Orange
3
Green
/White
4
Blue
5
Blue
/White
6
Green
7
Brown
/White
8
Brown
8.1 REQUIREMENTS FOR CAT5E/6/7 CABLES
A Cat5e/6/7 cable should meet the following requirements:
• The pins are connected 1:1.
Caution:
the cable pairs must be twisted to EIA/TIA- 568A (rare)
or EIA/TIA-568 B (common) pairs.
• Erroneous assignments cannot be found with a simple cable tester.
• The pins for the green pair of wires are not adjacent to one other.
• The cable must at the very least meet the CAT5 specifications and be suitable for Gigabit
transmission.
• The cable should meet one of the following standards: Class D ISO/IEC 11801:2002
or EN 50173-1:2002. Schema EIA/TIA-568 B.
• Only use shielded installation cable with min. cross section of 24 AWG throughout
the length.
• The shield should be contiguous and connected to both ends. A shielded patch cable is
allowed for connection to the device.
Schema EIA/TIA-568 B
Содержание MASTERflex KT-6012
Страница 35: ...kvm tec 35 Misprints errors and technical changes reserved 2 INSTALLATION OF THE EXTENDER ...
Страница 36: ...36 kvm tec Misprints errors and technical changes reserved 2 INSTALLATION OF THE EXTENDER ...
Страница 46: ...46 kvm tec Misprints errors and technical changes reserved 3 EXTENDER SETTINGS 3 5 1 DDC MAIN SINGLE ...
Страница 47: ...kvm tec 47 Misprints errors and technical changes reserved 3 EXTENDER SETTINGS 3 5 2 DDC SECOND DUAL ...
Страница 64: ...64 kvm tec Misprints errors and technical changes reserved 3 EXTENDER SETTINGS single dual ...
Страница 68: ...68 kvm tec Misprints errors and technical changes reserved 3 EXTENDER SETTINGS ...
Страница 88: ...88 kvm tec Misprints errors and technical changes reserved 11 NOTES ...