background image

TracPhone V7

1

Elevation Limit Switch Replacement Instructions

TracPhone

®

 

V7 Elevation Limit Switch 

Replacement Instructions

The following instructions explain how to replace the elevation limit 
switch in a TracPhone V7.

Tools Required

a.

Turn off and unplug the modem and control unit.

b.

Using a #2 Phillips screwdriver, remove the #10-32 

screws securing the radome to the baseplate. Carefully 

lift the radome straight up until clear of the antenna 

assembly and set it aside in a safe place.

Figure 1  Removing the Radome

• #1 Phillips screwdriver

• #2 Phillips screwdriver

• Needle-nose  pliers

CAUTION

For your own safety, be sure to disconnect power from all wired 
components before performing this procedure.

 #10-32 Screw 

  Limit Switch 

54-0517 Rev. A