Appendix C: Grounding and RF protection
Alternative grounding for aluminum hulls
161
CCCC
Gr
ounding
and
RF
C.6 Alternative grounding for aluminum hulls
The following guidelines assume a two-wire, isolated grounding
arrangement; that is no part of the circuit, in particular the battery negative, is
connected to any ground potential or equipment.
C.6.1 Grounding the terminal
The terminal must be grounded with the short antenna cable and a grounding
kit. Further, the terminal must be grounded at its grounding stud to ensure a
proper grounding if the short antenna cable is disconnected.
The ground connection must be established at a dedicated RF ground (either
capacitively or electrically coupled). Remember to make the antenna ground
connection at the
same electrical ground potential
as the terminal (see
).
The terminal provides galvanic isolation (as required) from its input power
terminals to the chassis/grounding stud. This way the isolated grounding
arrangement is maintained.
C.6.2 Grounding the antenna
If the mounting base of the antenna is electrically connected to the hull (or
any other ground potential than the terminal), the antenna must be isolated at
its mounting bolts by means of shoulder bushings and washers - see
page 169. This is done in order to prevent DC currents flowing in the hull thus
causing electrolytic corrosion.
However, a ground connection must be established via one of the mounting
bolts using a separate ground cable. The ground cable must be routed parallel
and in close proximity to the shielded coax cable hence connecting the
antenna to the terminal Grounding kit. A tinned heavy gauge wire (min. 6
mm
2
) can be used for this purpose - see page 162.
Содержание FB250
Страница 13: ...Table of contents xii ...
Страница 77: ...Chapter 3 Connecting power 64 Connecting power ...
Страница 105: ...Chapter 5 Starting up the system 92 Operating the system ...
Страница 129: ...Chapter 6 Service and repair 116 Replacing modules in 34 3052B antenna ...
Страница 139: ...Chapter 7 Troubleshooting 126 Logging of events ...
Страница 147: ...Appendix B Technical specifications 134 FB500 antenna B 2 3 Antenna outline dimensions FB500 in 26 66 cm dome ...
Страница 148: ...Appendix B Technical specifications FB500 antenna 135 BBBB Technical specifications FB500 in 35 89 cm dome ...
Страница 154: ...Appendix B Technical specifications FB250 antenna 141 BBBB Technical specifications FB250 in 19 48 cm dome ...
Страница 165: ...Appendix B Technical specifications 152 TracPhone terminal ...
Страница 197: ...Glossary 184 ...