Figure 4: Not all devices are synchronized via MagiSync in this setup.
panel. If all your hardware is placed in one Kvaser MagiSync Group, then you are
ready to go.
When connected correctly, all units are synchronized achieving a high precision
virtual clock accurate to the microsecond.
3.4
CAN connection
The Kvaser U100S-X3 has one CAN channel.
The CAN connector for the Kvaser U100S-X3 is the 16-pin OBDII Type B plug
which has the pinning described in Table 2.
Figure 5: OBDII Type B CAN connector.
OBDII pin number
Function
4
GND
6
CAN_H
14
CAN_L
Table 2: OBDII pin configuration (showing only connected pins).