Kvaser T-Cannector Expansion L User’s Guide
8 (18)
Figure 4:
Pinout of D-SUB9 plug.
SHIELD
V+
AUX-4
AUX-3
GND
CAN-H
CAN-L
AUX-2
AUX-1
P1
P2
P3
P4
120R
60R
SW
LED
5K6
390KD
07
V+
GND
DC INPUT
Figure 5: Schematic over the Kvaser T-cannector v2 (Base unit).
3.1
Power Distribution
The Kvaser T-cannector v2 (Base unit) may be powered from an external DC
power supply, via a 2.1 x 5.5 mm connector, providing a power source for Kvaser
CAN interfaces. The Kvaser T-cannector v2 (Base unit) may also distribute power
via V+ in any of the D-SUB9 connectors.
3.2
LED Indicators
The Kvaser T-cannector v2 (Base unit) has one red power LED indicator, see
Figure 6 on Page 9.
Kvaser AB, Mölndal, Sweden — www.kvaser.com