Kvaser U100-X1 User’s Guide
9 (21)
J1939-13 Pin
Function
A
GND
B
Not connected
C
CAN_HI
D
CAN_LOW
E
SHIELD
F-J
Not connected
Table 2: J1939-13 Type II pin configuration.
3.4
CAN bus termination
Every CAN bus must be terminated with a 120 Ohm resistor at each end of the
bus. The Kvaser U100-X1 does not contain any CAN bus termination, because
their inclusion could cause severe disturbance in a system which is already
correctly terminated.
For laboratory or testing use, the exact value of the termination resistors is not
always critical. Sometimes a single terminator is sufficient. For production, proper
termination is essential. If you see error frames on the bus, you should check the
termination.
To save yourself a lot of trouble, always terminate the CAN
bus properly.
3.5
Power supply
The Kvaser U100-X1 is powered through the USB connector.
Kvaser AB, Mölndal, Sweden — www.kvaser.com