44
|
52
Clubmax FB4 series - v150120
Kvant Lasers s.r.o.
EN
4. Power up the system as normal.
5. Create Yellow beam effect (point) and check visually whether the Red beam hits the exact centre of the Green beam
on the surface of dichroic filter DF3. If not, use dichroic mount DF1 to adjust the beam path accordingly (see diagram
below). To adjust the dichroic mount use the two adjustment knobs – each works for one axis.
6. Create Cyan beam effect (point) and check visually whether the Blue beam hits the exact centre of the Green beam
on the surface of dichroic filter DF3. If not, use dichroic mount DF2 to adjust the beam path accordingly. To adjust the
dichroic mount use the two adjustment knobs – each works for one axis.
7. Create Green beam effect (point) and check visually whether the beam hits exact centre of the bottom scanning
mirror. If not, use dichroic mount DF4 to adjust the beam path accordingly. To adjust the dichroic mount use the two
adjustment knobs – each works for one axis.