Auto Width Eye:
When the width adjust eye measures the door,
it displays the measurement in the top right
hand box under
Measured Width.
If the actual width of the door does not match
the result from the feedback, follow the steps
below:
1.
Click the
Combine with Base
, to set base to 0
as a reference.
2.
Once this number is combined with the Base
number, click on
+/- to Offset
. A number pad
will be displayed.
3.
If the feedback (Measured Width) number is
less than the actual door width, enter a
posi-
tive
number then click the check mark.
4.
If the feed back (Measured Width) number is
greater than the door width, enter a
negative
number then click the check mark.
5.
Once this is done, click Main button and
select the preset width and re-run the door.
Repeat steps 3-5 until Measure Width is the
same number as the door.
6.
After calibration is completed, click
Com-
bine with Base
to store data.
Description of User Interface Screens