V-DOG2

 

Ver1.0

 

 

User Manual for AC Voltage & Frequency Detector 

 
 
 
 
 
 

 

 
 
 

 

 

Содержание V-DOG2

Страница 1: ...CS INDUSTRY CO LTD TEL 886 7 8121771 FAX 886 7 8121775 Website www kutai com tw Headquarters No 3 Lane 201 Chien Fu St Chyan Jenn Dist Kaohsiung 80664 TAIWAN V DOG2 Ver1 0 User Manual for AC Voltage Frequency Detector ...

Страница 2: ...pecifications 3 SECTOIN 2 OPERATOR PANEL 2 1 General 3 2 2 Display Screen 3 2 3 Panel Buttons 4 2 4 Panel LED Indicators 4 SECTOIN 3 OPERATION 3 1 Overview 4 3 2 Programming Settings 4 3 3 Voltage Calibration 5 3 4 System Settings Selection Table 5 3 5 Electrical Specifications 5 SECTOIN 4 INSTALLATION INSTRUCTIONS 4 1 General 6 4 2 External Appearance Dimensions Installation Drawings 6 SECTOIN 5 ...

Страница 3: ...requirements of a power system These features can be set through a user friendly operating panel interface All user and factory settings are permanently saved and will not be lost due to power failure Feature 1 Full phase Over voltage Under voltage Lost phase sensing The V DOG2 control module can detect each phase voltage in the power supply Users can set their own over voltage and under voltage r...

Страница 4: ...Ds on the control panel indicate different power failure conditions Refer to the following illustrations for details LED indications Power Supply Voltage Frequency Normal Over Voltage Under Voltage Over Frequency Under Frequency SECTION 3 OPERATION 3 1 Overview This section will introduce the operation mode and user functions of the V DOG2 control module It is divided into two main parts Programmi...

Страница 5: ...calibrate Step 5 Press the increase button and the decrease button to enter the voltage reading from the meter Step 6 It is necessary to press the Setting button to change to the next phase to be calibrated or until End appears on the screen To end the program immediately press and hold the Setting button for 4 seconds to exit the program Step 7 If the display shows FAIL it means that the calibrat...

Страница 6: ..._______________________________________________________ 6 V DOG2 SECTION 4 INSTALLATION INSTRUCTIONS 4 1 General The V DOG 2 controller is designed for front panel mounting 4 2 External Appearance Dimensions Installation Drawings Units mm ...

Страница 7: ..._______________________________________ V DOG2 7 SECTION 5 WIRING CONNECTION ILLUSTRATIONS 5 1 3 phase system connection illustration J4 1 2 3 6 9 6 4 5 10 3 4 5 J5 7 8 1 2 J1 J2 J3 1 2 2 3 3 1 4 1 2 3 AC Power Source R S T Auxiliary output 50 500V A B C ...

Страница 8: ..._________________________________________________________ 8 V DOG2 5 2 Single phase system connection illustration J4 1 2 3 6 9 6 4 5 10 3 4 5 J5 7 8 1 2 J1 J2 J3 1 2 2 3 3 1 4 1 2 3 L1 L2 AC Power Source 50 500V Auxiliary output A B C ...