ECU-04

 

SECTION 6 : CONNECTION DETAILS AND TYPICAL WIRING DIAGRAM 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Battery (+)

Battery (-)

Strater "ON"

Accessories "ON"

Engine "Pre-Heat"

Ignition &

Accessories

Start

Pre-Heat

Stop

Heater

SW-ON

30A

30A

30A

20A

Remote

Start Switch

Open-STOP

Close-START

 AC Input from Generator

From 100 to 240Vac

Aux. Dry Contact

Open-When Engine Running
Close-When Engine Stop

Starter

Generator

Key Switch

 

Remote

Start Switch

Open-STOP

Close-START

Battery (+)

Battery (-)

 AC Input from Generator

From 100 to 240Vac

30A

30A

30A

20A

Start

Pre-Heat

Stop

Aux. Dry Contact

Open-When Engine Running
Close-When Engine Stop

Starter

Generator

Key Switch

To Carburetor

SW-OFF

Strater "ON"

Accessories "ON"

Ignition &

Accessories

 

Содержание ECU-04

Страница 1: ...ICS INDUSTRY CO LTD TEL 886 7 8121771 FAX 886 7 8121775 Website www kutai com tw Headquarters No 3 Ln 201 Qianfu St Qianzhen Dist Kaohsiung City 806037 Taiwan ECU 04 Ver1 0 Control Unit for Key Switch Type Generator ...

Страница 2: ...n t release the battery when engine is running Never feed charge motor voltage directly into controller to prevent damage to the controller caused by high charge voltage SECTION 3 SPECIFICATIONS ITEM DESCRIPTION DC Supply 12 Vdc ECU 05 12V Max Input 18 Vdc 24 Vdc ECU 05 24V Max Input 36 Vdc Alternator Input Voltage Range 100 240 Vac 10 Alternator Input Frequency Range 50 60 Hz Static Power Consump...

Страница 3: ... with 1 25 seconds range Please refer to the generator user s guide 4 8 seconds are recommended Please refer to Figure 1 below L1 Remote start activated indicator LED Please refer to Figure 1 below L2 Engine running normal indicator LED Please refer to Figure 1 below L3 Start fail indicator LED Please refer to Figure 1 below SW ON for use on Diesel Engine with Pre Heat OFF for use on Gasline Engin...

Страница 4: ...A 20A Remote Start Switch Open STOP Close START AC Input from Generator From 100 to 240Vac Aux Dry Contact Open When Engine Running Close When Engine Stop Starter Generator Key Switch Remote Start Switch Open STOP Close START Battery Battery AC Input from Generator From 100 to 240Vac 30A 30A 30A 20A Start Pre Heat Stop Aux Dry Contact Open When Engine Running Close When Engine Stop Starter Generat...

Отзывы: