background image

 

___________________________________________________________________________________________ 

4

 

EA230

 

 

VR

VR

RHEOSTAT

1K 0.5W

EXTERNAL
VOLT. ADJ.

EA230

E+

E-

FIELD

EXC.

110V

0V

T

S

N

R

Open  60Hz

Close 50Hz

HZ

HZ

 

 

T

S

N

HZ

EA230

E+

110V

0V

VR

E-

VR

EXC.

FIELD

EXTERNAL
VOLT. ADJ.
RHEOSTAT

1K 0.5W

HZ

Open  60Hz

Close 50Hz

 

Interconnection Diagram, 120 / 208 V Nominal, 

3-Phase, 4-Wire 

Figure 2 

Interconnection Diagram, 120 / 240 V Nominal, 

1-Phase, 3-Wire 

Figure 3 

FIELD

 

WARNING 

Please make sure you have read and understand the 
contents  of  the  instruction  manual  prior  to 
installation.  Incorrect  wiring  connection  may  result 
in  irreversible  damage  to  the  product  and  other 
equipments. 

This  Automatic  Voltage  Regulator  is  not  equipped 
with  loss-Sensing  Protection  function  /  Over 
Excitation  Protection.  An  additional  Over-Voltage 
Protection device for load may be required to avoid 
possible  damage  to  the  equipment  or  severe 
personal injury or death.

 

Operational Test 

Figure 4 

 

  Use only the replacement fuses specified in this user manual. 

  Appearance and specifications of products are subject to change for improvement without prior notice. 

Содержание EA230

Страница 1: ...anfu St Qianzhen Dist Kaohsiung City 80664 Taiwan EA230 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Leroy Somer R230 All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer ...

Страница 2: ...00 Hz Voltage Regulation Less than 1 with 4 engine governing Dimensions 140 0 L x 75 0 W x 51 0 H mm Build Up Voltage 6 Vac residual volts at power input terminal Weight 310 g 2 EMI Suppression Internal electromagnetic interference filtering ATTENTION 1 AVR can be mounted directly on the engine genset switchgear control panel or any position that will not affects operation For dimension reference ...

Страница 3: ...age may oscillate hunt 2 3 6 Rotated the front panel STAB control CCW until the system start oscillating and then rotate CW just past the point where oscillation occurred 2 4 System START UP 2 4 1 Perform preliminary set up as described in the above paragraphs ATTENTION The AVR reading AC voltage are all average value 2 4 2 Start prime mover and bring up to rated speed RESULT Voltage should build ...

Страница 4: ...Please make sure you have read and understand the contents of the instruction manual prior to installation Incorrect wiring connection may result in irreversible damage to the product and other equipments This Automatic Voltage Regulator is not equipped with loss Sensing Protection function Over Excitation Protection An additional Over Voltage Protection device for load may be required to avoid po...

Отзывы: