Kustom JCLEPA4200 Скачать руководство пользователя страница 2

ENGLISH

Danger
Exposure to extremely high noise levels may cause a
permanent hearing loss. Individuals vary considerably to
noise induced hearing loss but nearly everyone will lose
some hearing if exposed to sufficiently intense noise for a
sufficient time.

The U.S. Government's Occupational Safety and Health
Administration (OSHA) has specified the following
permissible noise level exposures:

According to OSHA, any exposure in the above permissible
limits could result in some hearing loss. Ear plugs or
protectors in the ear canal or over the ears must be worn
when operating this amplification system in order to prevent
a permanent hearing loss. If exposure in excess of the limits
as put forth above, to insure against potentially harmful
exposure to high sound pressure levels, it is recommended
that all persons exposed to equipment capable of inducing
high sound pressure levels, such as this amplification
system, be protected by hearing protectors while this unit is
in operation.

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE
OF NON-INSULATED "DANGEROUS VOLTAGE" WITHIN THE
PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE
TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE
OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING)
INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT.

1. Read all safety and operating instructions before using this

product.

2. All safety and operating instructions should be kept for

future reference.

3. Read and understand all warnings listed on the operating

instructions.

4 . Follow all operating instructions to operate this product.
5. This product should not be used near water, i.e. Bathtub,

sink,swimming pool, wet basement, etc.

6. Only use dry cloth to clean this product.
7. Do not block any ventilation openings, It should not be

placed flat against a wall or placed in a built-in enclosure
that will impede the flow of cooling air.

8.

Do not install this product near any heat sources ;such

as,radiators, heat registers, stove or other apparatus
(including heat producing amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or

grounding-type plug. A polarized plug has two blades with
one wider than the 0ther.A grounding-type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety If the provided plug
does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.

10. Protect the power cord being walked on or pinched,

particularly at Plugs, convenience receptacles and the point
where they exit from the apparatus. Do not break the ground
pin of the power supply cord.

11 . Only use attachments specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket,

or table specified by the manufacturer or
sold with the apparatus. When a cart is
used, use caution when moving cart/
apparatus combination to avoid injury
from tip-over.

13. Unplug this apparatus during lightning storms or when

unused for long periods of time.

14. Care should be taken so that objects do not fall and liquids

are not spilled into the unit through the ventilation ports or
any other openings.

15. Refer all servicing to qualified service personnel. Servicing

is required when the apparatus has been damaged in any
way; such as, power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally or has been dropped.

16. WARNING: To reduce the risk of fire or electric shock, do not

expose this apparatus to rain or moisture.

17. The MAINS plug or an appliance coupler is used as the

disconnect device, the disconnect device shall remain
readily operable.

IMPORTANT SAFETY INSTRUCTIONS

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO

NOT REMOVE CHASSIS. NO USER-SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.

CAUTION

APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING
AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES,
SHALL BE PLACED ON THE APPARATUS.

DURATION PER DAY (HOURS)

SOUND LEVEL (dB)

8

6

4 3 2 1

90 93 95 97 100 103

S 3 1 2 5 A

2

Содержание JCLEPA4200

Страница 1: ...Tuck n Roll Kustom P A system that Country music icon Johnny Cash once owned This new model not only captures that classic vibe but also offers top notch tone and dependable performance Inside this manual you ll find handy information about the product features and specifications We wish you many years of enjoyment with your Kustom JCLEPA4200 ...

Страница 2: ...stove or other apparatus including heat producing amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the 0ther A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consu...

Страница 3: ...ansport le support le trépied la console ou la table spécifiés par le constructeur ou vendus avec l appareil Lors de l utilisation d un chariot bouger avec précaution l ensemble chariotlappareil afin d éviter les dommages d un renversement 13 Débrancher cet appareil lors d orages ou s il n est pas utilisé pendant une longue période 14 Des précautions doivent être prises afin qu aucun objet ne tomb...

Страница 4: ...als for that channel 1 4 Line High Impedance Input MASTER SECTION MASTER VOLUME Control MASTER REVERB Control TAPE CD VOL Control Jewel Light LOW Control MID Control HIGH Control This may be used as either a high impedance microphone input or a line level device such as tape players CD players effects returns or radios It will also allow connection from an active electric guitar bass or keyboard I...

Страница 5: ...he reverb mix These RCA jacks are line level outputs for hooking up a device to record from the mixer Both channels are summed into mono for compatibility The signals are taken pre master section meaning that they are before the master tone and master volume do not include the PLAY signal 15 and are without reverb The impedance is 1 K ohms 10 dBV The fuse is located in the AC inlet housing just to...

Страница 6: ...PRE MIC PRE GAIN AMP GAIN AMP GAIN AMP GAIN AMP Volume Volume Volume Volume TONE TONE TONE TONE SIGNAL FLOW DIAGRAM Reverb Reverb Master MIX AMP GAIN AMP Main Master MAIN BUSS Reverb BUSS Fault Sensor POWER AMP POWER LIMITER Playback Speaker Protection MASTER TONE MID LOW HIGH Microphone Microphone Microphone Microphone Line Line Line Line Record Output Playback Line Output Speaker A Speaker B 6 ...

Страница 7: ...ctromagnetic Compatibility Product family standard for Audio Video Audio visual and entertainment Lighting Control Apparatus EN60065 1994 Safety requirements for main operated electronic and related apparatus for household and similar general use Following the provisions of EU Council Directive s 72 73 EEC and 89 336 EEC We the undersigned hereby declare that the equipment specified above conforms...

Страница 8: ...Kustom Amplification Inc PO BOX 568 Hebron KY USA 888 4 KUSTOM 888 458 7866 Web www kustom com ...

Отзывы: