V. LED STATUS INDICATORS
1. BATTERY CONNECTED
: Indicates that a battery of proper polarity is connected to the charger
output terminals
2. FAN ON
: Indicates that the fan is operating. Fan operates whenever output exceeds 10 amperes.
Fan turns off when output current decreases below 5 amperes
3. POWER
: Indicates that AC voltage is present
VI. BATTERY SELECTOR SWITCH
Allows selection between Lead-Acid and AGM style batteries. The default factory setting of the switch
is set to in the Lead-Acid position.
WIRING
I. BATTERY CHARGER WIRING INSTRUCTIONS
1.
Refer to Installation Wiring Diagram I and II.
2.
Refer to Wiring Specifications to determine the recommended wire size and maximum lengths.
Using a smaller gauge may cause overheating of the terminal. Additional information is available
upon request if longer, larger wiring is required.
3. Make sure the position of the Battery Selector Switch matches your battery type. The switch pro-
vides for operation in Lead-Acid or AGM style batteries. Refer to Installation Wiring Diagram III.
4.
Double check all wiring before applying AC power to input terminal.
5. Apply AC power (shoreline power) to input terminal and observe that the charger is operating.
6. Verify that the battery voltage appears at the charger output terminals. A minimum of 6 volts is
required to start the charger
II. WIRING SPECIFICATIONS
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
4
Length of Wire to Battery (feet)
Battery Charger Connections
V.
BA
T +
A.
PU
M
P +
CO
M
-
V.
BA
T +
A.
PU
M
P +
CO
M
-
V.
BA
T +
A.
PU
M
P +
CO
M
-
Wire # Gauge (awg)
8
14
8
6
14
6
4
12
4
Wire Ferrule Used
09
1-
TE
RF
ER
81
2
09
1-
TE
RF
EB
14
8
09
1-
TE
RF
ER
81
2
09
1-
TE
RF
EB
61
2
09
1-
TE
RF
EB
14
8
09
1-
TE
RF
EB
61
2
no
ne
09
1-
TE
RF
EY
10
12
no
ne
0-5
5 - 10**
10 - 20*
* Consult factory if length of wire to battery is longer than 20 feet
** Supplied with wire terminal hardware for 10 foot installation