6
Electrical
Specification
Model No.
Item
Inquire
Inquire
Inquire
Output
Characteristics
Efficiency max.
88%
89%
90%
Short-Circuit
Protection
1 Sec Shutdown
Output Waveform
Pure Sine Wave (THD < 5%@ Normal Load)
Signal and
Control
Remote Controller
Panel Unit
CR-8 / CR-16 (optional)
LED Indicator
Red / Orange / Green LED
Dry Contact
Terminal
By a relay
Remote Control
Terminal
6-port Green terminal (for inverter ON / OFF)
Protection
Input Protection
Over / Under Voltage, Reverse Polarity (Internal Fuse)
AC Output
Protection
Short-Circuit, Overload
Others
Over / Under Temperature Protection
(by Heat sink Tempe80
℃
/-20
℃
)
Environment
Operating Temp.
-20
℃
~40
℃
Storage Temp.
-30
℃
~70
℃
Storage Temp. &
Humidity
10 ~95% RH
Safety & EMC
Safety Standards
Certified EN 60950-1
EMC standards
Certified EN 55022; EN 55024; EN 61000-3-2, -3-3
EN 61000-4-2, 3, 4, 5, 6, 8, 11
E-mark
Certified CISPR 25; ISO 11452-2; ISO 7637-2
Dimension(WxHxD)
200mm X 83mm X 330mm
Weight
2.6 KG
Cooling
Temperature & Load Controlled cooling Fan
AC Transfer Function Accessories
TR-40 (optional)
Table 2.
450-0700-0
for Output 200/220/230/240 VAC Specification.
Note
:
Voltage range
:
Please refer to Figure 1
Normal load Condition
:
Vin =12.5V/25V/50V,
Vo=200/220/230/240 VAC 80% Full load (PF=1.0)
Operating temperature
:
Please refer to Figure 2
All manuals and user guides at all-guides.com