Installation Wiring Diagram
WIRE SIZE CHART
CONNECTION
ITEM
DEFINITION
WIRE SIZE
COM
BATTERY
COMMON
NEGATIVE CHARGING LEAD
FOR CHARGING BATTERIES
AND BATTERY SAVER LOAD
12 AWG
BAT 1
BATTERY
#1
POSITIVE CHARGING LEAD
FOR BATTERY # 1
12 AWG
BAT 2
BATTERY
#2
POSITIVE CHARGING LEAD
FOR BATTERY # 2
12 AWG
B.S.
BATTERY
SAVER
POSITIVE LEAD FOR BATTERY
SAVER LOADS.
16 AWG
AUTO
PUMP+
AUTO
PUMP
AUTO PUMP, POSITIVE
14 AWG
AUTO
PUMP-
AUTO
PUMP
AUTO PUMP, NEGATIVE
14 AWG
IMPORTANT : Wire size is
for a maximum length of 10
feet. If wiring is to be longer,
larger wiring is required. Ad-
ditional information is avail-
able on request.