BATTERY SAVER & INDICATOR

A 5 ampere BATTERY SAVER  is built into the charger. When connected as shown

in the installation wiring diagram, loads on the battery such as radios and recharge-

able hand lights are automatically switched to the BATTERY SAVER when power

is applied to the charger.  The BATTERY SAVER allows more efficient charging by

removing these loads.  A BATTERY SAVER overload indicator alerts the operator

that the BATTERY SAVER load has exceeded 5 amperes.

WHEN A BATTERY SAVER OVERLOAD OCCURS:

a. Remove the loads for approximately two minutes

b. Reduce the load to 5 amperes or less

c. Reapply the load to the BATTERY SAVER

No fuses are required or provided as the BATTERY SAVER contains an automatic

circuit breaker.

AUTOMATIC CURRENT LIMITING

When batteries are severly discharged, some battery chargers can be overloaded

due to the high charging current required. The Auto Charge 4000 contains an

automatic current limit. This current limits the output current to the rated 40 amperes

when charging a deeply discharged battery or if the starter cranks the engine while

charging. The current limiter thus eliminates the need for an ignition interlock

circuit.

Содержание 091-89

Страница 1: ... 631 567 0314 TOLL FREE 800 346 0857 FAX 631 567 5826 AUTO CHARGE 4000 AUTOMATIC BATTERY CHARGER 3 YEAR WARRANTY NOTE This charger is designed for vehicles with dual batteries and negative ground INPUT 120 volt 50 60 Hz 8 amps OUTPUT 40 AMPERES MODEL 091 89 12 file 091 89 12 p65 Rev A 10 27 2004 ...

Страница 2: ......

Страница 3: ... CHARGE CONTROLS ELECTRONIC REMOTE SENSING The Auto Charge 4000 contains two independent charge controls one for each battery Automatic electronic remote sensing measures the true voltage of each battery eliminating the need for the additional sense wires The output current of any charger is inherently a series of pulses whose frequency is determined by the power line frequency Therefore there are...

Страница 4: ...SAVER OVERLOAD OCCURS a Remove the loads for approximately two minutes b Reduce the load to 5 amperes or less c Reapply the load to the BATTERY SAVER No fuses are required or provided as the BATTERY SAVER contains an automatic circuit breaker AUTOMATIC CURRENT LIMITING When batteries are severly discharged some battery chargers can be overloaded due to the high charging current required The Auto C...

Страница 5: ...nded period of charging NOTE If a battery is being discharged with an external load of 1 5 to 6 amperes across it s terminals the bar graph may move down 1 or 2 levels This does not indicate a defective battery To avoid this connect all external loads to the BATTERY SAVER terminals Loads connected to the BATTERY SAVER will be powered either from the BATTERY SAVER power supply when the A C power is...

Страница 6: ...Saver Loads 5 amps max When the charger is disconnected from 120 volts AC the Battery Saver loads automatically are connected to battery 1 BATTERY SAVER POWER SAVER BATTERY BAT 2 BAT 1 POSITIVE COM REMOTE DISPLAY 4 3 2 1 OVERLOAD A C POWER 10 27 2004 Installation Wiring Diagram Strip insulation 15 32 so that wire strands are flush with end of eyelet 2 places NOTE Minimum wire size on charger outpu...

Страница 7: ...res not required Number of Charger Outputs 2 Number of Battery Saver Outputs 1 Battery Saver Output 12 volts D C 5 amperes Max Indicators Power Red LED indicates 120 volts power applied Battery Saver Overload Yellow LED indicates Battery Saver load greater than 5 amperes Bar Graph indicates charger output and condition of each battery Weight 24 lbs ...

Страница 8: ...charge any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped Kussmaul Electronics Company Inc shall have no liability for dam ages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The pur chaser by the acceptance of the equipment assumes all liability for any da...

Отзывы: