background image

Battery Saver & Indicator

      A 3 ampere BATTERY SAVER  is built into the charger. When connected as

shown in the installation wiring diagram, loads on the battery such as radios and

rechargeable hand lights are automatically switched to the BATTERY SAVER

when power is applied to the charger.  The BATTERY SAVER allows more efficient

charging by removing these loads.  A BATTERY SAVER overload indicator alerts

the operator that the BATTERY SAVER load has exceeded 3 amperes.

WHEN A BATTERY SAVER OVERLOAD OCCURS:

a. Remove the loads for approximately two minutes

b. Reduce the load to 3 amperes or less

c. Reapply the load to the BATTERY SAVER

No fuses are required or provided as the BATTERY SAVER contains an electronic

overload interrupter.

Remote Battery Charge Condition Indicator

      This remote indicator shows the charge condition of the battery in 10 levels from

“LOW CHARGE” to “FULLY CHARGED”.  This device indicates a  defective battery

when a bar graph does not rise to the “FULLY CHARGED” level after an extended

period of charging.

NOTE:  If a battery is being discharged with an external load of 1.5 to 4

amperes across it’s terminals, the bar graph may move down 1

or 2 levels. This does not indicate a defective battery.

To avoid this, connect all external loads to the BATTERY SAVER

terminals.

Loads connected to the BATTERY SAVER will be powered either from

the BATTERY SAVER power supply when the A.C. power is “ON”, or

they will be connected to the battery when the A.C. power is “OFF”.

Содержание 091-56

Страница 1: ...NICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 BOOK 091 56 12ac100 TEL in NY 631 567 0314 TOLL FREE 800 346 0857 FAX 631 567 5826 AUTO CHARGE 1000 AUTOMATIC BATTERY CHARGER INPUT 115 volt 50 60 Hz 3 5 amps OUTPUT 15 AMPERES MODEL 091 56 12 4 16 2002 ...

Страница 2: ...off Automatic Current Limiting When batteries are severely discharged some battery chargers can be over loaded due to the high charging current required The Auto Charge 1000 con tains an automatic current limit This circuit limits the output current to the rated 15 amperes when charging a deeply discharged battery or if the starter cranks the engine while charging The current limiter thus eliminat...

Страница 3: ... fuses are required or provided as the BATTERY SAVER contains an electronic overload interrupter Remote Battery Charge Condition Indicator This remote indicator shows the charge condition of the battery in 10 levels from LOW CHARGE to FULLY CHARGED This device indicates a defective battery when a bar graph does not rise to the FULLY CHARGED level after an extended period of charging NOTE If a batt...

Страница 4: ... LEAD FOR BATTERY 14 AWG B S BATTERY SAVER POSITIVE LEAD FOR BATTERY SAVER LOADS 16 AWG IMPORTANT Wire size is for a maximum length of 10 feet If wiring is to be longer larger wiring is required Ad ditional information is avail able on request AUTO CHARGE 1000 Battery Saver Loads 3 amps max When the charger is disconnect from 120 volts AC the Battery Saver loads automati cally are connected to the...

Страница 5: ......

Страница 6: ...ires not required Number of Charger Outputs 1 Number of Battery Saver Outputs 1 Battery Saver Output 12 volts D C 3 amperes Max Indicators Power Red LED indicates 120 volts power applied Battery Saver Overload Yellow LED indicates Battery Saver load greater than 3 amperes Bar Graph indicates charger output and state of charge of battery Weight 16 lbs ...

Страница 7: ... 3 years from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for dam ages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The pur chaser by the acceptance of the equipm...