background image

Chassis

Ground

091-28

AIR EJECT

Pressure Switch

Check Valve

Tee Fitting

Indicator

Air to Vehicle

Master Switch

Black

Orange

Red

INSTALLATION INSTRUCTIONS

Model 091-28-IND AIR EJECT INDICATOR

KUSSMAUL ELECTRONICS COMPANY, INC.

170 CHERRY AVENUE,  WEST SAYVILLE,  NEW YORK,  11796-1221  USA

SINCE 1967, DESIGNERS OF INNOVATIVE PRODUCTS

TEL. In NY: 

                   TOLL FREE: 

                  FAX: 

631 567-0314

800 346-0857

631 567-5826

1. Install pressure switch in side of Tee fitting.

2. Install Check Valve in Tee fitting as illustrated, note direction of check valve.

3. Install Tee fitting subassembly in Air Eject as shown.

4. Wire on side of pressure switch to chassis ground with Black Wire.

5. Wire second side of pressure switch to indicator with Orange Wire.

6. Wire second side of indicator to a sw12 volt supply. If it is desired to illuminate the

        indicator whenever the air line is connected, even with the master switch OFF, the power

       to the indicator may be taken directly from the battery.

November 12, 2004