44
Installing the Inverter/Charger
This guide for use by qualified personnel only.
Step 8: Testing Your Installation
There are several tests to be performed for testing your
installation. These tests will verify that:
•
the
$XWR3RZHU
works in invert mode
•
the
$XWR3RZHU
works in charge mode
•
the
$XWR3RZHU
works in AC bypass mode
If the test fails at any point, go to “Step 7: Performing Checks
Prior to Initial Start-Up” on page 4
and go through the
checklist again to check the installation. Then perform the test
again. If the test fails again, see the troubleshooting section in
the
$XWR3RZHU
Sine Wave Inverter/Charger Owner’s Guide.
1. Close the DC disconnect switch or the DC circuit breaker
to supply DC power to the
$XWR3RZHU
.
Wait for all the lights on the front panel to flash on and
off, indicating that the unit has successfully initialized (10
to 30 seconds).
If the bulb does not come on, make sure the voltage at the
DC terminals on the
$XWR3RZHU
is correct, as described
in “Step 7: Performing Checks Prior to Initial Start-Up”
on pag
H
3
ELECTRICAL SHOCK HAZARD
Do
not
use
the
INVERTER ENABLE
button
on
the
Auto Power
to
de-
energize
the
unit.
This
button
and
buttons
on
optional
accessories,
such
as
the
SCP,
do
not
disconnect
DC
or
AC
power
sources
to
the
Auto Power
.
Failure to follow these instructions can result in death or serious injury.
Figure 16
Auto Power
Front Panel
Testing in Invert Mode
To test the
$XWR3RZHUL
n invert mode, using a 100 watt
light bulb as the test load:
KANBUS INTERFACE
STACKING
INVERTER/CHARGER
CLEAR FAULT
RESET
INVERTER
ENABLE
INVERTER
ENABLED
AC IN
FAULT
GEN
SUPPORT
CHARGING WARNING
Auto Power
2000
Содержание 091-269-12-2000
Страница 2: ......
Страница 31: ...1 Blank Page for future use...
Страница 88: ...170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com...