WIRING AND SWITCH SETTINGS

I.  BATTERY CHARGER WIRING INSTRUCTIONS

1. 

Refer to Installation Wiring Diagram I & II.

2. 

Refer to Wiring Specifications to determine the recommended wire size and maximum lengths.

Using a smaller gauge may cause overheating of the terminal.  Additional information is available 

upon request if longer, larger wiring is required.

3. 

Torque DC output connector. Refer to Specifications.

4.  Set the front panel switches for the appropriate battery type, charge method, safety timer value, 

battery saver mode and parasitic load requirement. Refer to Sections III, IV, V and VI.

5. 

Double check all wiring and switch settings before applying AC power to input terminal.

6.  Apply AC power (shoreline power) to input terminal and observe that the charger is operating. 

7.  Verify that the battery voltage appears at the charger output terminals.

II.  WIRING SPECIFICATIONS

III.  BATTERY TYPE SELECTION SWITCHES

 

    

Switches 1 and 2 should be set to match the battery chemistry.

 

Lead-Acid - Both switches down (off) - factory default setting

 

Gelled Electrolyte (Gel Cell) - Switch 1 down (off) and Switch 2 up (on)

 

AGM - Switch 1 up (on) and Switch 2 down (off)

 

Odyssey® - Both switches up (on)

IV.  FLOAT / 3-STEP CHARGE MODE SELECTION SWITCHES

Switches 3 and 4 should be set for the desired charging method and 3-step safety timer period. The 

safety timer period begins when AC power is applied to the charger. The absorption phase of 3-step 

charging terminates when the safety timer expires, or when the PLC threshold setting is reached.  If no 

PLC settings are set, the threshold is 0.5A.  The charger then switches to, and remains in, float mode 

while AC power is applied.

 

Float Charge Only - Both switches down (off) - factory default setting

 

3-Step with 1 Hour Safety Timer - Switch 3 down (off) and Switch 4 up (on)

 

3-Step with 5 Hour Safety Timer - Switch 3 up (on) and Switch 4 down (off)

 

3-Step with 10 Hour Safety Timer - Both switches up (on)

170 Cherry Avenue

West Sayville, NY 11796

www.kussmaul.com

Ph: 800-346-0857

Fax: 631-567-5826

[email protected]

4

Length of Wire to Battery (feet)

Battery Charger Connections

CO

M -

V. B

A

T 1

 +

B.S. +

CO

M -

V. B

A

T 1

 +

B.S. +

CO

M -

V. B

A

T 1

 +

B.S. +

Wire # Gauge (awg)

14 14 16 12 12 16 10 10 16

0 - 5

5 - 10

10 - 20*

* Consult factory if length of wire to battery is longer than 20 feet

Содержание 091-215-12

Страница 1: ...our mobile device for more information INSTRUCTION MANUAL INPUT 120 Volt 60 Hz 3 5 Amps OUTPUT BATTERY 1 15 or 18 Amps OUTPUT BATTERY SAVER 3 Amps 3 YEAR WARRANTY MODEL 091 215 12 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com Optional Deluxe Displays Supplied with Bar Graph Display ...

Страница 2: ...ger from the AC source before attempting any maintenance or cleaning 7 LOCATION OF CHARGER The charger should be mounted on a wall vehicle floor ventilated compart ment or other suitable surface as close to the batteries to be charged as possible Do not block the char ger s fan or air intakes Do not mount the charger directly over the batteries as fumes may cause exces sive corrosion The area shou...

Страница 3: ... voltage This battery voltage is compared to a standard and any error is detected and used to control the charger output at the desired level There is no trickle charge therefore no danger of overcharging and water boil off III AUTOMATIC CURRENT LIMITING Some battery chargers can be overloaded due to the high charging current required when batteries are severely discharged The Auto Charge 1000 PLC...

Страница 4: ...setting Gelled Electrolyte Gel Cell Switch 1 down off and Switch 2 up on AGM Switch 1 up on and Switch 2 down off Odyssey Both switches up on IV FLOAT 3 STEP CHARGE MODE SELECTION SWITCHES Switches 3 and 4 should be set for the desired charging method and 3 step safety timer period The safety timer period begins when AC power is applied to the charger The absorption phase of 3 step charging termin...

Страница 5: ...e switches control the point at which the charger will terminate the absorbtion phase of the 3 step charging cycle The possible settings are 0 1 2 4 6 8 10 or 12 amperes If there are no parasitic loads or if they are all are on the Battery Saver then set these three switches to the down off position This is the factory default setting VII REMOTE BATTERY CHARGE CONDITION INDICATOR Standard equipmen...

Страница 6: ... Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com DIP SWITCH SETTINGS NOTE The charger is shipped with all DIP switches in the down position This configuration is for Float Charging of a Lead Acid battery with Battery Saver and Parasitic Load Compensation turned off Legend on front panel of charger This is what the dip switch should look lik...

Страница 7: ...tery Saver loads are automatically connected to the vehicle battery 40 Amp fuse or Waterproof Circuit Breaker Kussmaul Part 090 0040 0 Install near the battery 9 3 1 BATTERY 1 AC Line Cord installed on back of unit Remote Indicator 1 RED 20AWG 2 BLACK 20AWG 3 WHITE 20AWG 4 GREEN 20AWG 1 5 4 3 2 AUTO CHARGE 1 2 3 4 REMOTE INDICATOR 1 2 3 4 5 6 7 8 POWER SYSTEM R 0 AMPS 0N FLOAT LEAD GELL AGM ODY 0F...

Страница 8: ...Saver Loads 3 amps max When the charger is disconnected from AC power the Battery Saver loads are automatically connected to the vehicle battery 40 Amp fuse or Waterproof Circuit Breaker Kussmaul Part 090 0040 0 Install near the battery 9 3 1 BATTERY 1 AC Line Cord installed on back of unit AUTO CHARGE 1 2 3 4 REMOTE INDICATOR 1 2 3 4 5 6 7 8 POWER SYSTEM R 0 AMPS 0N FLOAT LEAD GELL AGM ODY 0FF 1 ...

Страница 9: ...cates charger is in current limit normal operation Solid Off indicates normal operation Brief Flash once every 2 seconds indicates 3 step boost mode operation Cooling Fan The whisper quiet cooling fan exhausts air from the rear of the charger When the Battery Saver is enabled it is continuously on while AC power is applied to the charger It turns on at 4 amperes of output current and turns off at ...

Страница 10: ...OUTLINE DRAWING 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 9 ...

Страница 11: ...ment bar graph display indicates output current 4 LED s to show the condition of the batteries Indicator is housed in a watertight bezel Bezel is available in 6 different colors Red White Blue Yellow Gray and Black Specify color choice when ordering IV RECOMENDED 40 AMP WATERPROOF CIRCUIT BREAKER MODEL 090 0040 0 Combines switching and circuit breaker function Compact size and surface mount config...

Страница 12: ...aterial or defects which become apparent in normal use within 3 years from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kuss maul Electronics Compan...

Отзывы: