background image

INSTALLATION WIRING DIAGRAM

IMPORTANT: Charger output wire size is 14 awg.  Wire size is for a maximum length of 20 feet.
If wiring is to be longer, larger wiring is required. Additional information is available on request.

115 or 230 voltage se-
lector switch.

NOTE:

Do not apply 230 volts to
the charger with the se-
lector switch in the 115
volt position serious dam-
age may result

FUSE

5 AMP

POWER

INPUT

OUTPUT

L

N

BAT 1

BAT 2

REMOTE

Chassis
Ground

Chassis
Ground

Chassis
Ground

Line

Neutral

Ground

A.C. Input Power

Optional Economy
Indicator

Optional Bar-graph 
Indicator
091-11-127-XX

YELL

OW

RED

BLA

CK

+

+

Bat 2

Gnd

Bat 1

KUSSMAUL

CHARGING

MAINS

ON

BATTERY

EURO

CHARGER

091-90-012-XX

Содержание 091-117

Страница 1: ...TY KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 1221 FILE 091 117 xx PM6 5 DATE 8 30 2005 TEL in NY 631 567 0314 TOLL FREE 800 346 0857 FAX 631 567 5826 EURO CHARGER II AUTOMATIC BATTERY CHARGER MODEL 091 117 XX ...

Страница 2: ... CHARGER FEATURES Completely automatic operation charges battery on demand Input voltage switch selectable 115 volt or 230 volts Output voltage regulated eliminates overcharging battery Output current limited to protect charger from overloading Optional charge indicators INSTALLATION The EURO CHARGER II automatic battery charger should be installed in an area with adequate ventilation Mount the ch...

Страница 3: ...e se lector switch NOTE Do not apply 230 volts to the charger with the se lector switch in the 115 voltpositionseriousdam age may result FUSE 5 AMP POWER INPUT OUTPUT L N BAT 1 BAT 2 REMOTE Chassis Ground Chassis Ground Chassis Ground Line Neutral Ground A C Input Power Optional Economy Indicator Optional Bar graph Indicator 091 11 127 XX Y ELLOW RED BLACK Bat 2 Gnd Bat 1 KUSSMAUL CHARGING MAINS O...

Страница 4: ...t Current see chart Charge Indicator 0 15 amps 5 Weight 11 lbs Model Output Current Output Voltage Input Voltage Input Current Charge Indicator 091 117 12 12 Amps 12 230 115 50 60 Hz 1 3 2 6 Amps 15 amps 091 117 24 6 Amps 24 230 115 50 60 Hz 1 3 2 6 Amps 8 amps OUTLINE DRAWING ...

Страница 5: ...use within 3 years from the date the equipment was shipped Equipment is to be returned shipping charges prepaid and will be returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of th...