background image

  -PRESS ACCEPT

The Bit Rate can be changed by accessing the SET UP 

category and selecting  “SET CAN BUS SPEED” use Up/

Down arrows to set changes in VALUES

.

                                        

 

 

                              

 

Additional Information:

• 

Low Oil Pressure only updated if Rpm>100 (ie: engine    

running)

• 

Battery Voltage limited to 99.9 (only 3 digits for display)

• 

Oil Pressure limited to 99 PSI (only 2 digits for display

)

• 

Engine Temperature 32 deg F (0 deg C) minimum 

(avoid negative numbers when in Deg C)

• 

MaxRpm only updated if Rpm > 10 (help prevent   

exceeding max number of Flash writes)

• 

“LOST COMM” message displayed if no J1939 data 

received for 10 or more seconds.  Restore display on valid 

data or any key

• 

A press of any button activates/restarts 5 minute alarm  

“silence” timer

• 

Don’t allow INSTRUMENT hours to increment in Sleep 

mode

SPECIFICATIONS

Power Supply:

 9.50 to 33.00 VDC, @ 80mA

Operating Temperature:

 32° to 122° F (0° to 50° C) 

Size:

 4.3” x 4.3” x 3.5” deep (110 x 110 x 89 mm) 

Display Data:

 

Engine RPM: 

0000-9999 ( or as provided by J1939) 

On screen title “ENGINE RPM

Oil Pressure:

 0199 PSI (or as provided by J1939). 

On screen title “OIL LSI” (factory default).User select-

able for Millibars or European standard. On Screen 

“MBRS”.

Engine Temp:

100-250° F ( or as provided by J1939) 

On screen title “ ENGINE TEMP F” (factory default0. 

User selectable for Centigrade, on screen title 

”ENGINE TEMP C”

Battery Volts:

 9.5 - 33.0 On screen title 

”BATT VOLTS

”. 

Displays “COMM LOSS” & red 

dashes with loss of J1939 DATA. No alarm on COMM 

LOSS.

Accuracy:

 

Battery Volts: As provided by J1939

Engine RPM : As provided by J1939

Engine Temperature: As provided by J1939

Oil Pressure: As provided by J1939

Alarms:

  Engine RPM, Low/High Oil Pressure, High Engine   

                     Temp. and Low/High Battery Volts

Alarm Output:

 12 VDC, 50 mA max.

III. DETAILS:

 Displays details page.  SN, Min/Max, 

Alarm Values, etc.

IV. ABOUT: 

Displays splash screen, SW version, 

HW version and copyright information.

Back

Back

Back

Quit

Kussmaul Electronics

VOTT ENGINE MONITOR

S/W= 20   H/W= XX

www.kussmaul.com

COPR. 2011,2016 Cruzpro LTD.

170 Cherry Avenue

West Sayville, NY 11796

www.kussmaul.com

Ph: 800-346-0857

Fax: 631-567-5826

[email protected]

4

Отзывы: