4. Operation Method :

Connect the meter leads and measuring wire together 
(Do not use hand directly). At that time, meter will show 
the phase and phase order.

Open phase 
check by LED

All 3 orange 
LED light

All 3 orange 
LED light

Measuring 
result

Correct phase
(CW)

Reverse phase
(CCW)

Open phase 
(one phase only)

Orange LED for 
open phase are off

Phase order 
check by LED

Green LED light

Red LED light

Both green and 
red LED are off

Buzzer

Intermittent 
beep

Continuous 
beep

Continuous 
beep

3. Specification :

1. 

Open phase check by LED :

    

3  Orange  LED,  show  R  Phase,  Y  Phase,  and B 

    Phase Respectively.
2. 

Phase sequence check through LED :

    A Red LED and a Green LED
3. 

Wrist Strap :

    Wrist strap to avoid the meter from falling.
4. 

Measuring Lead :

    Red lead is corresponding R Phase (L1,R); Yellow is 
    corresponding     Y     Phase     (L2,S);      Green    is 
    corresponding  B  Phase (L3, T) Carrying case.

CCW

CW

R

Y

B

L1

L2

L3

(R)

(S)

(T)

1

2

3

b

4

PHASE SEQUENCE INDICATOR